-25-
v7.0
Software
Possible error codes for this function:
1: not registered, ME is not currently searching for a new operator to register to
2: not registered, but ME is currently searching for a new operator to register to
3: registration denied
4: unknown
6: not registered, ME is not currently searching for a new operator to register to
8: not registered, but ME is currently searching for a new operator to register to
9: registration denied
10: unknown
12: if error setting APN
13: if error setting login
14: if error setting password
15: if error activating GPRS connection
16: if error getting socket status
17: Socket with an active data transfer connection
18: Socket suspended
19: Socket suspended with pending data
20: Socket listening
21: Socket with an incoming connection. Waiting for the user accept or shutdown command.
22: Socket in opening process. The socket is not closed but still not in Active or Suspended.
23: if error in Socket Configuration
24: if error in Socket Configuration Extended 3
25: if error sending the open command
26: if timeout opening the socket