Defining User Variables
User Defined Constants and Remarks
15-12
Using the LI-6400
15
User Defined Constants and Remarks
In addition to defining equations, the ComputeList File can be used to make
extra user defined constants and remarks. Recall that the system provides
some predefined ones (that you can rename) for your use (see
on page 9-12). The techniques described in this section would be
used to add extra ones.
User Constants
A numerical user constant can be defined by using the function
UCON(0)
in the equation definition string. For example, Figure 15-8 defines two con-
stants, named ÒPlot#Ó and ÒRateÓ.
The argument of the UCON function is the initial value of the user constant.
User Remarks
If you wish a constant to contain letters and punctuation, in addition to num-
bers, then youÕll need a string remark. User remarks are defined just like user
constants, except instead of UCON, use
UREM(n)
where
n
is the desired maximum string length of the remark.
Using Constants and Remarks
To include user defined prompts and remarks in the prompt list, use the
Prompt List Editor, and add them, once they are defined (see
##7001F0 "Plot#" "Plot ID Number" "UCON(0)"
##7002 "Rate" "Fert rate (lbs/acre)" "UCON(50)"
##10 "(U/S)" "flow:area ratio"
" flow_um / area_cm2 / 100.0"
Figure 15-8. Two user defined constants with IDÕs 7001 and 7002. Since Plot#
is to be an integer value, we specify a format of F0 so it will be displayed that
way.
Содержание LI-6400
Страница 1: ...Using the LI 6400 Portable Photosynthesis System ...
Страница 15: ...Part I The Basics ...
Страница 16: ......
Страница 174: ...Making Measurements Answers to Questions 4 56 Using the LI 6400 4 ...
Страница 175: ...Part II Useful Details ...
Страница 176: ......
Страница 200: ...Standard Tools Power ON Hooks 5 24 Using the LI 6400 5 ...
Страница 214: ...Real Time Data Real Time Graphics 6 14 Using the LI 6400 6 ...
Страница 234: ...Environmental Control Light Control 7 20 Using the LI 6400 7 ...
Страница 244: ...Light Sensor Considerations Gallium Arsenide Phosphide GaAsP Sensor 8 10 Using the LI 6400 8 ...
Страница 288: ...Data Logging Making Your Own AutoPrograms 9 44 Using the LI 6400 9 ...
Страница 289: ...Part III Working With Files ...
Страница 290: ......
Страница 312: ...The LPL File System Troubleshooting 10 22 Using the LI 6400 10 ...
Страница 340: ...Downloading Files Using a Data Capture Program 11 28 Using the LI 6400 11 ...
Страница 375: ...Part IV Configuration Issues ...
Страница 376: ......
Страница 420: ...Defining User Variables Old Style vs New Style 15 18 Using the LI 6400 15 ...
Страница 454: ...Using an Energy Balance Further Reading 17 12 Using the LI 6400 17 ...
Страница 455: ...Part V Maintenance Troubleshooting ...
Страница 456: ......
Страница 572: ...Troubleshooting Useful Information 20 46 Using the LI 6400 20 ...
Страница 587: ...Diagnostics and Utilities Sys Utility Programs Using the LI 6400 21 15 EBVpd t C guess EBSatVap _EBvap_kPa ...
Страница 593: ...Part VI Programming ...
Страница 594: ......
Страница 622: ...Programming with LPL Compiler Directives 22 28 Using the LI 6400 22 ...
Страница 846: ...Index I 16 Using the LI 6400 ...