background image

Steps 1 – 4 should be performed with the 

device turned OFF. Once the unit has been 

turned ON, do not remove electrodes 

without first turning OFF the device. 

IMPORTANT!

PAGE 2  

QUICK REFERENCE GUIDE

2

CONNECT ELECTRODES 

TO LEAD WIRES

Firmly insert

the red or black 

end of the lead 

wire pin (it 

doesn’t matter 

which one) into 

the electrode 

connectors.

Make sure no bare metal of the pins are exposed.

3

CONNECT LEAD WIRES 

TO TOP OF DEVICE

This unit operates 

with one or two 

sets of electrodes.  

When using one set, 

plug lead wire into 

Channel 1 on top 

of the unit. Use 

Channel 2 to operate 

a second set if 

directed by your 

healthcare provider. 

4

PLACE ELECTRODES

ON SKIN

6

SELECT THE 

THERAPEUTIC MODE

Remove electrodes from 

protective backing. Keep 

backing to properly store 

electrodes after use.

Apply electrodes to the 

exact site indicated by 

your doctor or therapist. 

Make sure the skin at the 

application site is clean 

and dry. 

There are 4 therapeutic modes available: TENS, EMS, 

IF and MIC. Press the 

M

 button and continue to 

press until you have advanced to the appropriate 

therapeutic mode.

Consult your physician for your suitable 

therapeutic mode.

Press the 

S

 button to enter and cycle through 

to each setting state.

SET THERAPEUTIC PROGRAM

There are 4 programs available in the TENS therapeutic mode:  

-

 

Burst,  

-

 

Normal,  

-

 

Pulse Width Modulation, and  

M1 

-

 

Pulse Rate Modulation.  The therapeutic 

program can be selected by pressing the 

s

 and 

t

 buttons. When you choose to 

M

 program, program 

M

 outside of the box will be flashing.

SET CYCLE TIME (OPTIONAL)

Cycle time is adjustable from 

5

 to 

30

 seconds. Only modulation has this parameter 

setting. Press 

S

 button to enter this menu, and then press the 

s

 and 

t

 buttons to 

adjusting the setting.

SET TIMER

Press the 

S

 button to enter this setting. The treatment time is adjustable from 

to 

60

 minutes or Continuous. Press the 

s

 and 

t

 buttons to adjust setting. You 

can set the timer to “Continuous” mode by pressing the 

s

 control when it shows 

60 minutes. The output will be shut off when time is up. If in continuous mode, you 

need to manually turn off device.

SET PULSE WIDTH

Pulse Width is adjustable from 

50

 uS to 

300

 uS. Press 

S

 button to enter this menu, 

then press the 

s

 and 

t

 buttons to adjust the setting.

5

TURN DEVICE ON 

See 

Electrode Placement Guide

 for more information.

1

INSERT BATTERY

Press arrow and slide battery compartment 

cover open. Insert 9V battery, matching the 

+ and – ends to those in unit. 

The included AC adapter may 

also be used as a power source.

TENS SETTING

2

1

3

4

SET PULSE RATE

Pulse rate is adjustable from 

1

 Hz to 

150

 Hz (0.5 Hz to 5 Hz for Burst). Press the 

S

 

button after scrolling through and completing all settings to start the therapy program. 

The 

s

 and 

t

 buttons can be used to increase 

s

 or decrease 

t

 the intensity level.

5

1

2

3

4

3

5

 

Check that electrodes are securely placed on 

the skin before activating device. Press and release the 

     

  

       button in the center of the unit to turn it ON.

LG  QUAD Combo

QUICK REFERENCE GUIDE 

PAGE 3

Press the 

S

 button to enter and cycle through 

to each setting state.

SET THERAPEUTIC PROGRAM

There are 3 programs available in EMS therapeutic mode:  

-

 

Synchronous, 

-

 

Alternate and 

-

 

Delay. The therapeutic program can be selected by pressing the 

s

 and 

t

 buttons. When you choose to 

D

 program, program 

D

 outside of the box 

will be flashing.

SET TIMER

Press the 

S

 button to enter this setting. The treatment time is adjustable from 

to 

60

 minutes or Continuous. Press the 

s

 and 

t

 buttons to adjust setting. You 

can set the timer to “Continuous” mode by pressing the 

s

 control when it shows 

60 minutes. The output will be shut off when time is up. If in continuous mode, you 

need to manually turn off device.

SET PULSE WIDTH

The pulse width determines the length of time. Each electrical signal is applied 

through the skin, which controls the strength and sensation of the stimulation.  

Press the 

S

 button to enter this setting. The pulse width is adjustable from 

50

 to 

300

 uS. Press the 

s

 and 

t

 buttons to adjust the setting.

SET PULSE RATE

The pulse rate determines how many electrical impulses are applied through the skin 

each second. Press the 

S

 button to enter this menu. Adjust the setting by pressing the 

s

 and 

t

 buttons. The pulse rate is adjustable from 

1

 Hz to 

150

 Hz.

SET DELAY TIME (OPTIONAL)

Delay time is adjustable form 

1

 to 

10

 seconds. Only the “Delay” therapeutic program 

has this parameter setting. Press the 

S

 button to enter this menu, and then press the 

s

 and 

t

 buttons to adjust the setting.

SET RAMP TIME

The ramp time controls the time of output current that increase from 

0

 to the setting 

level, and from the setting value to 

0

. When the ramp time is set, each contraction 

may be ramped up and down in order that the signals come on and come off gradually 

and smoothly. The ramp time is adjustable from 

1

 to 

6

 seconds.

SET CONTRACT TIME

The contract time controls the time of stimulation and can be adjusted. Press the 

S

 

button to enter this menu, and then press the 

s

 and 

t

 buttons to adjust the setting. 

Both channels’ stimulation is cycled on and off by the contraction and relaxation 

settings. The range is adjustable from 

1

 to 

60

 seconds.

EMS SETTING

2

1

3

4

1

2

3

2

4

5

Caution: Contract time does not include the ramp up and ramp down time, 

ON time = Ramp up + Contract time + Ramp down. 

SET RELAXATION (OFF) TIME

The off time controls the time of relaxation and can be adjusted. Press the 

S

 button to 

enter this menu, and then press the 

s

 and 

t

 buttons to adjusting the setting. Both 

channels’ stimulation is cycled on and off by the contraction and relaxation settings. 

The range is adjustable from 

0

 to 

60

 seconds.

Press the 

S

 button after scrolling through and completing all settings to start the 

therapy program. The 

s

 and 

t

 buttons can be used to increase 

s

 or decrease 

the intensity level.

6

7

5

8

6

7

8

IMPORTANT TIPS AND SAFETY FEATURES

The Safety Lock Feature             automatically activates after there is no operation in 

the panel for 30 seconds by locking out the ability to press the buttons. This is a safety 

feature to prevent accidental changes to your settings and to prevent accidental 

increases to the intensity levels. You can press either one of the 

t

 buttons to unlock 

the device.

Once you have activated the treatment timer, you can press the 

M

 button or the 

button to control stop the treatment.

Turn off the device 

by pressing and holding the power         on/off button for 

3 seconds. If in “lock” mode, press the 

t

 button to unlock the device and then press 

and hold the power         on/off button for 3 seconds to turn off.

The device will automatically power off after 2 minutes of inactivity in the panel.

Low battery indicator             

signals when battery is low.  Replace battery when 

stimulation feels weaker.

Live Pain Free, Live Good Today!