2 ) D e f e ct s o n d i s p l a y i n g f u n ct i o n
3 ) R e s e t D u r i n g o p e r a t i o n
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Main voltage
1. Measure mains voltage at the wall
outlet
2. Meaure voltage at the extended
outlet that the washer is plugged in
if the extended outlet is used and
voltage at the electrical outlet
is normal in the above.
Transfomer
1. Measure the secondary voltage of
the transfomer.
Controller
1. Defect of LED.
2. Defect of LED driving circuit.
3. Defect of micom.
Less than 85%
of the rating.
Less than 85%
of the rating
Less than
AC 10V
Low voltage.
The dia of the lead
wire is smaller or
many loads are
connected at the
same outlet
Defect of the
transfomer.
Defect of controller.
To explain that it is
caused by low voltage in
electric supply and
recommend using a
transfomer if voltage has
been continuously low.
To use a transfomer
having a enough
capacity if using
a transfomer.
Change the controller.
Change the controller.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Mains Voltage
1. Measure voltage of the outlet that the
washer is plugged into during wash and
spin.
2. Reset symptom happens at specific
time zone repeatedly.
3. Check whether a transfomerlent
power cut happens.
(Fluorescent lamp is
transfomeriently blinked.)
Less than
80% of the rating.
Mains voltage is too
low or size of a lead
wire is too small.
External noise
inrushed.
Explain that it is caused
by low voltage in electric
mains and recommend
using a suitable size of
leads.
Explain it is caused by
using environment.
(It happens when
equipment with high
frequency is used
around)
Explain it is a problem of
electric supply
environment.
40
Содержание WTS14BSL
Страница 18: ...3 4 WASHING PROGRAMS Course 18 ...
Страница 19: ...Course 19 ...
Страница 20: ...Course 20 ...
Страница 21: ...21 ...
Страница 22: ...3 5 OTHERS FUNCTIONS 1 SOAK Wash Course Course 22 ...
Страница 23: ...3 5 OTRAS FUNCIONES 2 TUB CLEAN Course Course Course Course Course Course Course Course Course 23 ...
Страница 24: ...3 5 OTRAS FUNCIONES 3 AIR DRY AIR DRY for your laundary 24 ...
Страница 26: ...3 5 OTRAS FUNCIONES 5 DELAY START RESERVATION Wash 26 ...
Страница 51: ...51 ...
Страница 53: ...F070 F090 F080 F020 F027 F001 F000 For Pump For Non Pump F020 F021 F040 Non Service Part ...
Страница 55: ...P No MFL69262915 August 2015 PRINTED IN THAILAND ...