INSTALLATION
Drainage (Optional)
The base-pan may overflow due to high humidity.
To drain the excess water, remove the drain cap
from the base pan of the unit and secure the
drain pipe.
1
Measure the space for installation to
assure a good fit. The air conditioner must
be installed firmly into place to prevent
vibration and noise.
2
Avoid exposure to direct sunlight.
3
Remove all obstacles from the rear of the
unit. There must be at least 50 cm (20 in.)
of cleared space around the rear of the
unit. Obstacles restricting the airflow may
reduce the cooling efficiency of the unit.
4
The unit should be installed with a slight tilt
towards the outside to allow condensed
water to drain. (About 10~15 mm or 1/4
bubble with Level)
1
Remove the rubber cap from the hole
under the base-pan.
3
Connect the drain hose to the outlet
located on the bottom of the drain pipe.
(You can purchase the drain hose or tubing
locally to satisfy your particular needs.
Drain hose is not supplied)
CAUTION
•
Take care when inserting the drain pipe.
Push away from the sharp edge to avoid
slipping and injuring yourself.
!
2
1
2
Press the drain pipe into the hole by
hanging and pushing.
Foam
Awning
Heat
radiation
Fence
Over 50 cm
Cooled air
10~15 mm
1/4 Bubble
Level
How to Install the Unit
CAUTION
•
The external grille must be exposed outside for
air discharge.
•
As the minimum installation height is 70cm.
Please be aware of some old buildings may not
meet this requirement of installation height.
!
(Minimum
70-150cm
height is 70cm)
installation
11
INSTALLATION
EN
Space for Outside Air Flow
NOTE
• Unit may be supported by a solid frame from
below or by a hanger from a solid overhead
support.
1
Prepare the hole in the wall so that the
bottom of the unit is well supported, the top
has minimum clearace and the air inlet
louveres have clearance as shown. Holes
from the outside through to the cavity
should be sealed. The unit should slope
down towards the rear by about 10~15 mm
to allow water formed during operation to
drain.
2
Install the unit into the wall and secure.
Ensure the foam seals are not damaged.
Flash, seal or fill gaps around the inside
and outside to provide satisfactory
appearance and protection against the
weather, insects and rodents.
CAUTION
• Use an assistant to help lift the unit and set
it in place. Lifting and maneuvering the unit
by yourself could result injury.
!
The Foam
(Around the unit)
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
AIR OUT
AIR IN
AIR IN
100 mm minimum
OPTION A
OPTION B
TOP VIEW
100 mm
DRAIN PIPE
EXTERNAL SUPPORT FRAME AT
BALANCE POINT OF RAC
ALTERNATIVELY, BRACKETS AS
ILLUSTRATED BELOW MAY BE
USED.
45° BRICK CUT AWAY
TO CLEAR LOUVRES
45° BRICK CUT AWAY
TO CLEAR LOUVRES
BRICK WALL
BRICK WALL
AIR IN
AIR OUT
AIR IN
FRONT
LOUVRE
100 mm
110~180 mm
Preferred method of installation into a timber
framed wall, partition or window.
STURDY TIMBER
FRAME ALL
ROUND UNIT
TIMBER FRAMED
WALL OR PARTITION
Installation of the Unit
Содержание W3NQ08UNNP1
Страница 26: ......
Страница 30: ...由於最少安裝高度為75厘米 需留意某些大廈的安裝高度或未能達到該要求 ...
Страница 33: ... 最少安裝高 度為75厘米 75 150厘米 由於最少安裝高度為75厘米 需留意某些大 廈的安裝高度或未能達到該要求 ...
Страница 46: ...23 ...
Страница 47: ...24 ...
Страница 48: ......
Страница 49: ......