7
SAFETY INSTRUCTIONS
EN
WARNING
.
•
.
•
•
Technical Safety
•
.
!
REFRIGERANT (FOR R32 ONLY)
10
INSTALLATION
Drainage (Optional)
The base-pan may overflow due to high humidity.
To drain the excess water, remove the drain cap
from the base pan of the unit and secure the
drain pipe.
1
Measure the space for installation to
assure a good fit. The air conditioner must
be installed firmly into place to prevent
vibration and noise.
2
Avoid exposure to direct sunlight.
3
Remove all obstacles from the rear of the
unit. There must be at least 50 cm (20 in.)
of cleared space around the rear of the
unit. Obstacles restricting the airflow may
reduce the cooling efficiency of the unit.
4
The unit should be installed with a slight tilt
towards the outside to allow condensed
water to drain. (About 10~15 mm or 1/4
bubble with Level)
1
Remove the rubber cap from the hole
under the base-pan.
3
Connect the drain hose to the outlet
located on the bottom of the drain pipe.
(You can purchase the drain hose or tubing
locally to satisfy your particular needs.
Drain hose is not supplied)
CAUTION
•
Take care when inserting the drain pipe.
Push away from the sharp edge to avoid
slipping and injuring yourself.
!
2
1
2
Press the drain pipe into the hole by
hanging and pushing.
Foam
Awning
Heat
radiation
Fence
Over 50 cm
Cooled air
10~15 mm
1/4 Bubble
Level
How to Install the Unit
CAUTION
•
The external grille must be exposed outside for
air discharge.
•
As the minimum installation height is 70cm.
Please be aware of some old buildings may not
meet this requirement of installation height.
!
(Minimum
70-150cm
height is 70cm)
installation
9
INSTALLATION
EN
Installation Overview
Tools Needed
NOTE
• Use 15 A circuit breaker.
Phillips-head
screwdriver
Flat-blade screwdriver
Pencil
Level
Tape measure
Cutting knife
Scissors
Main Power source
Foam
Drain pipe
Circuit Breaker
Use a circuit breaker
or time delay fuse.
INSTALLATION
Circuit Breaker Installation
Read thoroughly and follow all directions provided.
A circuit breaker must be installed between the power source and the unit if the plug is not used
(see illustration below).