How to Install the Unit
Preparation of the Cabinet
1
Measure the space for installation to assure
a good fit. The air conditioner must be
2
Avoid exposure to direct sunlight.
installed firmly into place to prevent vibration
and noise.
There must be at least 50 cm (20 in.) of
cleared space around the rear of the unit.
Obstacles restricting the airflow may reduce
the cooling efficiency of the unit.
3
Remove all obstacles from the rear of the unit.
towards the outside to allow condensed water
to drain. (About 10~15 mm or 1/4 bubble with
Level)
4
The unit should be installed with a slight tilt
Fence
Awning
Heat
radiation
Cooled air
1
3
Before installing the unit back into the
cabinet , remove the white styrofoam
shipping block from the compressor
(Applicable for some models).
CAUTION
●
The external grille must be exposed outside
for air discharge.
10~15 mm
Over 50 cm
Foam
70-150 cm
Level
1/4 Bubble
White styrofoam block
Shipping screws
Remove 4 screws which fasten the cabinet
at both sides and at the back. (Keep the
screws for later use.)
CAUTION
●
The unit is heavy. To prevent injury, use
proper lifting techniques when pulling unit
forward from cabinet. Obtain assistance
from another person if possible.
2
Slide the unit from the cabinet by gripping
the base pan handle and pulling forward
while bracing the cabinet.
9 EN
INSTALLATION