background image

OWNER’S MANUAL

AIR 

CONDITIONER

TYPE : WINDOW

EN    ENGLISH

Read this owner's manual thoroughly before operating the

appliance and keep it handy for reference at all times.

MODELS

W122HE  SC1

*MFL69716009*

MFL69716009

Rev.00_111220

www.lg.com

Copyright © 2020 LG Electronics Inc. All Rights Reserved.

Содержание W122HE SC1

Страница 1: ... EN ENGLISH Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times MODELS W122HE SC1 MFL69716009 MFL69716009 Rev 00_111220 www lg com Copyright 2020 LG Electronics Inc All Rights Reserved ...

Страница 2: ...tion of the Cabinet 10 Space for Outside Air Flow 11 Installations of the unit into the Cabinet 11 Drain Pipe 12 OPERATION 12 Control Panel and Remote Control 13 Wireless Remote Control 14 Ventilation 14 Air Direction 14 Slinger Fan 8 Installation Overview 9 How to Install the Unit 15 SMART FUNCTIONS 15 LG ThinQ Application 17 MAINTENANCE 17 Air Filter 18 TROUBLESHOOTING 18 Before Calling for Serv...

Страница 3: ...do not follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what may happen if the instructions are not followed IMPORTANT SAFETY INSTRUCTIONS WARNING INSTALLATION Before use the appliance must be properly installed as described in this manual Contact the authorized service technician for repair or maintenance o...

Страница 4: ...y be sharp Disconnect the power cord or circuit breaker before installing or servicing the appliance Keep packaging materials out of the reach of children These materials can pose a suffocation risk to children Store and install the product where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions Do not store or use gasoline or other flammable vapors and...

Страница 5: ...appliance is equipped with a three prong grounding plug Use this with a standard three slot grounding wall power outlet to minimize the hazard of electric shock The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded DO NOT CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER PLUG Attaching the adapter ground termi...

Страница 6: ...ow for an extended period of time could be hazardous to your health Stop using the remote control if there is a fluid leak in the battery If your clothes or skin are exposed to the leaking battery fluid wash off with clean water If the leaking battery fluid has been swallowed rinse the inside of the mouth thoroughly and consult a doctor Do not operate the appliance without the filter securely inst...

Страница 7: ...ard 4 Evaporator 5 Electric Heater 6 Brace 7 Condenser 8 Base Pan 1 Front Grille 2 Cabinet Vertical Air Deflector Horizontal Louver Horizontal Air Deflector Vertical Louver 3 4 5 6 Remote Control 7 Air Intake Inlet Grille 8 Air Filter Air Discharge 3 4 1 8 7 6 2 5 4 3 1 8 7 EN PRODUCT OVERVIEW ...

Страница 8: ...e Cutting knife Scissors Main Power source Circuit Breaker Use a circuit breaker or time delay fuse Read thoroughly and follow all directions provided A circuit breaker must be installed between the power source and the unit if the plug is not used see illustration below NOTE Use 20 A circuit breaker Screw Foam Drain pipe For Front Grille L 10 mm 1 EA L 30 mm 3 EA ...

Страница 9: ...talled with a slight tilt Fence Awning Heat radiation Cooled air 1 3 Before installing the unit back into the cabinet remove the white styrofoam shipping block from the compressor Applicable for some models CAUTION The external grille must be exposed outside for air discharge 10 15 mm Over 50 cm Foam 70 150 cm Level 1 4 Bubble White styrofoam block Shipping screws Remove 4 screws which fasten the ...

Страница 10: ...s and rodents 2 Install the cabinet into the wall and Unit may be supported by a solid frame from below or by a hanger from a solid overhead support FLASH OR SEAL AROUND EXTERNAL WALL FRAME OR ARCHITRAVE STURDY TIMBER FRAME ALL ROUND UNIT DRAIN CHUTE EXTERNAL SUPPORT FRAME AT BALANCE POINT OF RAC Preferred method of installation into a timber framed wall partition or window ALTERNATIVELY BRACKETS ...

Страница 11: ... the grille in until it snaps into place Installations of the unit into the Cabinet Power Cord Screw Screw The Foam The power cord must be connected to an independent circuit The green wire must be grounded When you detach the front grille from the cabinet push the grille to your right side and pull it toward you 11 EN INSTALLATION Drain Pipe In humid weather excess water may cause the base pan to...

Страница 12: ...y Saver AA Energía Cool Frío Cool Frío Fan Vent In this mode the fan circulates air but the compressor does not run Use the Fan Speed V vent button to set fan speed to High or Low In this mode you cannot adjust the set temperature 1 4 2 7 3 This mode is ideal on hot days to cool and dehumidify the room quickly Use the Temp buttons to set the desired room temperature and use the Fan Speed button to...

Страница 13: ...mpiar Filtro light NOTE control panel not the remote control This feature is a reminder to clean the air light turns on after 250 hours of operation filter for more efficient operation The LED The filter reset must be done using the The thermostat monitors room temperature to maintain the desired temperature The thermostat can be set between 60 F 86 F 16 C 30 C Press or arrows to increase or decre...

Страница 14: ...ing the direction The horizontal airflow is adjusted by moving the Touch the horizontal louvers to adjust the airflow levers of the vertical louvers to the left or right Direction up or down NOTE When the weather is extremely hot the unit may turn off automatically to protect the compressor This air conditioner is equipped with a slinger fan See drawing The fan s outer ring picks up the condensed ...

Страница 15: ...k properly depending on the Internet service provider The surrounding wireless environment can make the wireless network service run slowly The appliance cannot be registered due to problems with the wireless signal transmission Unplug the appliance and wait about a minute before trying again If the firewall on your wireless router is enabled disable the firewall or add an exception to it The wire...

Страница 16: ...his feature is only available on models with the or logo Use this feature to help you diagnose and solve problems with your appliance NOTE TM For reasons not attributable to LGE s negligence the service may not operate due to external factors such as but not limited to Wi Fi unavailability Wi Fi disconnection local app store policy or app unavailability The feature may be subject to change without...

Страница 17: ...ter then polish using liquid appliance wax NOTE To ensure continued peak efficiency the condenser coils outside of unit should be checked periodically and cleaned if clogged with soot or dirt from outside air For repair and maintenance contact a LG Electronics Customer Information Center See the warranty card for details or call 55 5321 1919 Have your model number and serial number available 17 EN...

Страница 18: ...g Air At the front of the unit you may hear the sound of rushing air being moved by the fan 3 Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation 4 Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation 5 Pinging or Swishing Droplets of water hitting condenser during normal...

Страница 19: ...If power failure occurs turn the mode control to off When power is compressor overload The air filter is dirty Clean the filter at least every 2 weeks See the MAINTENANCE Cleaning the Air Filter section The cooling coils are iced over Ice may block the air flow and obstruct the air conditioner from properly cooling the room Set the Fan Speed High at Fan or Cool mode The temp control may not be set...

Страница 20: ...ner is not connecting to the Wi Fi Noise when unit is Room too cold cooling Window vibration poor installation Refer to installation instructions or check with installer The Wi Fi router is too far from the air conditioner Move the router closer to the air conditioner or purchase and install a Wi Fi repeater signal booster Air movement sound This is normal If too loud set to lower FAN Speed Air co...

Страница 21: ...incorrectly The wireless network name SSID should be a combination of English letters and numbers Do not use special characters The router frequency is not 2 4 GHz Only a 2 4 GHz router frequency is supported Set the wireless router to 2 4 GHz and connect the appliance to the wireless router To check the router frequency check with your Internet service provider or the router manufacturer The dist...

Страница 22: ...Sor Juana Inés de la Cruz No 555 Col San Lorenzo Industrial Tlalnepantla de Baz Estado de México C P 54033 Página web http www lg com mx Tel 55 5321 1919 ...

Отзывы: