9
INSTALLATION
EN
How to Install the Unit
Space for Outside Air Flow
Unit Installation
1
Measure the space for installation to assure
a good fit. The air conditioner must be
2
Avoid exposure to direct sunlight.
installed firmly into place to prevent vibration
and noise.
There must be at least 50 cm (20 in.) of
cleared space around the rear of the unit.
Obstacles restricting the airflow may reduce
the cooling efficiency of the unit.
3
Remove all obstacles from the rear of the unit.
towards the outside to allow condensed water
to drain. (About 10~15 mm or 1/4 bubble with
Level)
4
The unit should be installed with a slight tilt
Fence
Awning
Heat
radiation
Cooled air
CAUTION
●
The external grille must be exposed outside
for air discharge.
10~15 mm
Over 50 cm
Foam
70-150 cm
Level
1/4 Bubble
100 mm minimum
AIR IN
AIR IN
AIR OUT
OPTION A
100 mm
100 mm
LOUVRE
FRONT
45
°
BRICK CUT AWAY
TO CLEAR LOUVRES
45
°
BRICK CUT AWAY
TO CLEAR LOUVRES
BRICK
WALL
AIR IN
AIR IN
BRICK
WALL
AIR OUT
TOP
VIEW
OPTION B
Stuff the foam between the top of the unit
and the wall to prevent air and insects from
getting into the room.
CAUTION
●
The power cord must be connected to an
independent circuit. The green wire must
be grounded.
The Foam