Problem
Possible Causes
Corrective Action
The air outlet on
the indoor unit is
discharging mist.
The cooled air from the air conditioner
makes mist.
•
When the room temperature decreases,
this phenomenon will disappear
Water leaks from
the outdoor unit.
In the heating operations, condensed
water drops from the heat exchanger.
•
This symptom requires installing a drain
hose under the base pan. Contact the
installer.
There is noise or
vibration.
A clicking sound can be heard
when the unit starts or stops due to
movement of the reversing valve.
Creaking sound: The plastic parts of
the indoor unit creak when they shrink
or expand due to sudden temperature
changes.
Flowing or Blowing sound: This is
conditioner.
•
These are normal symptoms. The noise will
stop.
The indoor unit
gives off an odor.
Odors (such as cigarette smoke) may
be absorbed into the indoor unit and
•
If the smell does not disappear, you need
contact the service center to clean your
heat exchanger.
The air conditioner
does not emit warm
air.
When Heating Mode starts, the vane
is almost closed, and no air comes
out, even though the outdoor unit is
operating.
•
This symptom is normal. Please wait until
the unit has generated enough warm air to
blow through the indoor unit.
The outdoor unit is in Defrosting
Mode.
•
In Heating Mode, ice/frost is built up on the
coils when the outside temperature falls.
This function removes a layer of frost on the
minutes.
Outside temperature is too low.
•
NOTE
•
Some functions may not be supported, depending on the model.
Voltage
Model
Frequency
Cooling
Heating
Power
Current
Power
Current
VM122H6 NJM0, USM0
VM242C6 NKM0, USM0
220 V~
220 V~
50/60 Hz
50/60 Hz
NOR. 1 095 W/
MAX. 1 280 W
NOR. 6,20 A/
MAX. 7,20 A
NOR. 2 010 W/
MAX. 2 420 W
NOR. 9,60 A/
MAX. 11,46 A
NOR. 975 W/
MAX. 1 300 W
NOR. 5,50 A/
MAX. 7,30 A
VM122C6 NJM0, USM0
-
-
-
-
220 V~ 50/60 Hz NOR. 1 095 W/
MAX. 1 280 W
NOR. 6,20 A/
MAX. 7,20 A
VM242H6 NKM0, USM0 220 V~ 50/60 Hz
NOR. 2 010 W/
MAX. 2 420 W
NOR. 9,60 A/
MAX. 11,46 A
NOR. 1 890 W/
MAX. 2 500 W
NOR. 9,10 A/
MAX. 11,84 A
VM182C6 NKM0, USM0
220 V~ 50/60 Hz NOR. 1 640 W/
MAX. 1 710 W
NOR. 7,40 A/
MAX. 8,10 A
NOR. 1 500 W/
MAX. 1 800 W
NOR. 6,82 A/
MAX. 8,52 A
-
-
220 V~ 50/60 Hz NOR. 1 640 W/
MAX. 1 710 W
NOR. 7,40 A/
MAX. 8,10 A
VM182H6 NKM0, USM0
50/60 Hz
50/60 Hz
VM121H6 NJM0, USM0 115 V~
NOR. 1 095 W/
MAX. 1 394 W
NOR. 9,82 A/
MAX. 12,13 A
MAX. 12,13 A
NOR. 975 W/
MAX. 1 327 W
NOR. 9,12 A/
MAX. 11,54 A
VM121C6 NJM0, USM0
-
-
115 V~
NOR. 1 095 W/
MAX. 1 394 W
NOR. 9,82 A/
VM182C6 NKM1, USM1
VM182H6 NKM1, USM1
26