1. Installation Places
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.
• Ensure that the spaces indicated by arrows
around front, back and side of the unit.
• Do not place animals and plants in the path of
the warm air.
• Take the air conditioner weight into account
and select a place where noise and vibration
are minimum.
• Select a place so that the warm air and noise
from the air conditioner do not disturb
neighbors.
More than
300 mm
Fence or
obstacles
More than 700 mm
More than 600 mm
More than
More than
300 mm
300 mm
More than
300 mm
Sunroof
Installation of Outdoor Unit
Installation of Outdoor Unit
2. Piping length and the elevation
n
Single Operation
If installed tube is shorter than 7.5 m, additional charging is not necessary.
Additional Refrigerant = (A-7.5)xAdditional refrigerant (g)
6
Air Conditioner
Outdoor unit
Indoor unit
A
B
Outdoor unit
Indoor unit
A
B
Unit : mm
Model
Capacity
Pipe Size
mm(inch)
Length A(m)
Elevation B(m)
Additional
refrigerant
(g/m)
Gas
Liquid
Standard
Max.
Standard
Max.
UU18W
5 kW
Ø 12.7(1/2)
Ø 6.35(1/4)
7.5
40
5
30
20
UU24W
7 kW
Ø 15.88(5/8) Ø 9.52(3/8)
7.5
50
5
30
40
UU30W
8 kW
Ø 15.88(5/8) Ø 9.52(3/8)
7.5
50
5
30
40
UU36W/UU37W
10 kW
Ø 15.88(5/8) Ø 9.52(3/8)
7.5
50
5
30
40
UU42W/UU43W
12.5 kW
Ø 15.88(5/8) Ø 9.52(3/8)
7.5
75
5
30
40
UU48W/UU49W
14 kW
Ø 15.88(5/8) Ø 9.52(3/8)
7.5
75
5
30
40
UU60W/UU61W
15 kW
Ø 15.88(5/8) Ø 9.52(3/8)
7.5
75
5
30
40
Содержание UU49W