Wiring Connection
The power cord
connected to the outdoor unit should be complied
withIEC 60245 or HD 22.4 S4 (This equipment shall be provided with a
cord set complying with the national regulation.
The connecting cable
connected to the outdoor unit should be
complied with IEC 60245 or HD 22.4 S4 (This equipment shall be
provided with a cord set complying with the national regulation.)
If the supply cord is damaged, it must be replaced by a special cord or assembly availible from the manufacturer of its service agent.
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
2
When the connection line between the indoor unit and
outdooor unit is over 40 m, connect the telecommunication
line and power line separately.
20 mm
GN/YL
35±
5 mm
10±3 mm
GN/
YL
20 mm
35±
5 m
m
10±3 mm
Installation Manual
11
ENGLISH
Model
Phase(Ø )
Area(mm
2
)
UU18W/24W/30W
1
2.5
UU36W/UU42W
/UU48W/UU60W
1
6
UU37W/UU43W
/UU49W/UU61W
3
2.5
• For wiring, use the designated power wire and connect firmly, then secure to prevent outside
pressure being exerted on the terminal block.
• Use an appropriate screwdriver for tightening the terinal screws. A screwdriver with a small head
will strip the head and make proper tighterning impossible.
• Over-tightening the terminal screws may break them.
When none are available, follow the instructions below.
• Do not connect wiring of different thicknesses to the power terminal block. (Slack in the power
wiring may cause abnormal heat.)
• When connecting wiring which is the same thickness, do as shown in the figure below.
u
Precautions when laying power wiring
Round pressure terminal
Power wire
Use round pressure terminals for connections to the power terminal block.
Outdoor
unit
Indoor
unit
1
2
3
1
2
3
CAUTION
!