6
Single CAC
Outdoor Unit
Standard Inverter - Synchro
3. Combination Table
̰
Possible combinations
Note
1. Possible indoor units: Single CAC indoor unit series
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.
• When using synchro operation
– Do not use wireless remote controller
– Use only one wired remote controller in the indoor units.
– Some Central controllers and some functions of central controller can not be available with synchrooperation.
2. Branch kits are required for operating Synchro models.
Possible combination of indoor units
Synchro
Duo
Trio
Quartet
IDU : INDOOR UNIT
ODU : OUTDOOR UNIT
BD : BRANACH
DISTRIBUTOR UNIT
REMO : WIRED REMOTE
CONTROLLER
MODEL
Cas- sette
Duct
Ceiling
Suspended
Cas- sette
Duct
Ceiling
Suspended
Cas- sette
Duct
Ceiling
Suspended
UU42W/UU43W
CT24
NP2(4)*2
CM24 N14*2
CB24L N32*2 CV24 NJ2*2
CT18
NQ2(4)*3
CM18 N14*3
CB18L N22*3 CV18 NJ2*3
CT12
NR2*4
CB12L N22*4
-
UU48W/UU49W
CT24
NP2(4)*2
CM24 N14*2
CB24L N32*2 CV24 NJ2*2
CT18
NQ2(4)*3
CM18 N14*3
CB18L N22*3 CV18 NJ2*3
CT12
NR2*4
CB12L N22*4
-
UU60W/UU61W
UT30
NP2(4)*2
UM30 N14*2
UV30 NJ2*2
CT18
NQ2(4)*3
CM18 N14*3
CB18L N22*3 CV18 NJ2*3
CT12
NR2*4
CB12L N22*4
-
UU70W
UT36
NN2*2
UM36 N24*2
UV36
NK2*2
CT24
NP2(4)*3
CM24 N14*3
CB24L N32*3 CV24 NJ2*3
CT18
NQ2(4)*4
CM18 N14*4
CB18L N22*4 CV18 NJ2*4
UU85W
UT42
NM2*2
UM42 N24*2
UV42 NL2*2
CT24
NP2(4)*3
CM24 N14*3
CB24L N32*3
CV24 NJ2*3
CT18
NQ2(4)*4
CM18 N14*4
CB18L N22*4 CV18 NJ2*4
Branch Kit
PMUB11A
PMUB111A
PMUB1111A
ODU
BD
IDU
IDU
REMO
ODU
BD
IDU
IDU
IDU
REMO
BD
IDU
IDU
IDU
IDU
ODU
REMO
Содержание UU48W U32
Страница 1: ...FDF Heat Pump 50Hz 410A 5CSL0 02C Replaces 5CSL0 02B P No MFL67502810 ...
Страница 3: ...General Information Single CAC Outdoor Unit FDF 1 Model Line Up 2 Nomenclature ...
Страница 8: ...Product Data Single CAC Outdoor Unit FDF Standard Inverter Standard Inverter Synchro Compact Inverter ...
Страница 37: ...Single CAC Outdoor Unit 3 Dimensions 30 Standard Inverter AUUW 18GAE UU18W UE4 Chassis code UE ...
Страница 41: ...Single CAC Outdoor Unit 3 Dimensions 34 Standard Inverter AUUW85LAE UU85W U74 Chassis code U7 ...
Страница 50: ...43 Single CAC Outdoor Unit Standard Inverter 5 Wiring Diagrams AUUW09GA0 UU09W UL0 AUUW12GA0 UU12W UL0 ...
Страница 51: ...Single CAC Outdoor Unit 5 Wiring Diagrams 44 Standard Inverter AUUW18GAE UU18W UE4 ...
Страница 52: ...5 Wiring Diagrams 45 Single CAC Outdoor Unit Standard Inverter AUUW24GAE UU24W U44 AUUW30GAE UU30W U44 ...
Страница 53: ...Single CAC Outdoor Unit 5 Wiring Diagrams 46 Standard Inverter AUUW366D2 UU36W UO2 ...
Страница 55: ...Single CAC Outdoor Unit 5 Wiring Diagrams 48 Standard Inverter AUUW368D2 UU37W UO2 ...
Страница 57: ...Single CAC Outdoor Unit 5 Wiring Diagrams 50 Standard Inverter AUUW70LAE UU70W U34 ...
Страница 58: ...5 Wiring Diagrams 51 Single CAC Outdoor Unit Standard Inverter AUUW85LAE UU85W U74 ...
Страница 126: ...6 Single CAC Outdoor Unit Compact Inverter 3 Dimensions AUUW18GC0 UU18WC UL0 Chassis code UL2 ...
Страница 127: ...3 Dimensions 7 Single CAC Outdoor Unit Compact Inverter AUUW24GC0 UU24WC UE0 AUUW30GC0 UU30WC UE0 Chassis code UE ...
Страница 128: ...Single CAC Outdoor Unit 3 Dimensions 8 Compact Inverter AUUW36GC0 UU36WC U40 Chassis code U4 ...
Страница 130: ...10 Single CAC Outdoor Unit Compact Inverter 5 Wiring Diagrams Models AUUW18GC0 UU18WC UL0 ...
Страница 131: ...5 Wiring Diagrams 11 Single CAC Outdoor Unit Compact Inverter Models AUUW24GC0 UU24WC UE0 AUUW30GC0 UU30WC UE0 ...
Страница 132: ...Single CAC Outdoor Unit 5 Wiring Diagrams 12 Compact Inverter Models AUUW36GC0 UU36WC U40 ...