5
ENG
ENGLISH
5
EXTERNAL CONTROL DEVICE SETUP
Communication Parameters
•
Baud rate : 9600 bps (UART)
•
Data length : 8 bits
•
Parity : None
•
Stop bit : 1 bit
•
Communication code : ASCII code
•
Use a crossed (reverse) cable.
Command reference list
(Depending on model)
COMMAND1 COMMAND2
DATA
(Hexadecimal)
COMMAND1 COMMAND2
DATA
(Hexadecimal)
01. Power*
k
a
00 to 01
15. Balance k
t
00 to 64
02. Aspect
Ratio
k
c
16. Color
(Colour)
Temperature
x
u
00 to 64
03. Screen
Mute
k
d
17. ISM
Method (Only
Plasma TV)
j
p
04. Volume
Mute
k
e
00 to 01
18. Equalizer j
v
05. Volume
Control
k
f
00 to 64
19. Energy
Saving
j
q
00 to 05
06. Contrast k
g
00 to 64
20. Tune
Command
m
a
07.
Brightness
k
h
00 to 64
21. Channel
(Programme)
Add/Del(Skip)
m
b
00 to 01
08. Color/
Colour
k
i
00 to 64
22. Key
m
c
Key Codes
09. Tint
k
j
00 to 64
23. Control
Backlight,
Control Panel
Light
m
g
00 to 64
10.
Sharpness
k
k
00 to 32
24. Input
select (Main)
x
b
11. OSD
Select
k
l
00 to 01
25. 3D (Only
3D models)
x
t
12. Remote
Control Lock
Mode
k
m
00 to 01
26. Extended
3D (Only 3D
models)
x
v
13. Treble
k
r
00 to 64
27. Auto
Configure
j
u
14. Bass
k
s
00 to 64
* Note: During playing or recording media, all commands except Power (ka) and Key (mc) are not
executed and treated as NG.
With RS232C cable, TV can communicate "ka command" in power-on or power-off status. but with
USB-to-Serial converter cable, the command works only if TV is on.
Содержание UN8570PUC
Страница 33: ......