ENGLISH

Installer Setting - Checking Address of Central Control

With the MODE button pressed, press the RESET button.

1

With the PLASMA button pressed, press the RESET button.

1

Press the ON/OFF button toward the indoor unit 1 time, and the indoor unit will

display the set address in the display window.

- The address display time and method can differ by the indoor unit type.

2

Reset the remote controller to use the general operation mode.

3

By using the TEMPERATURE SETTING button, set the indoor unit address.

- Setting range : 00 ~ FF

2

After setting the address, press the ON/OFF

button toward the indoor unit 1 time.

3

The indoor unit will display the set address to complete the address set-

ting.

- The address display time and method can differ by the indoor uint type.

Reset the remote controller to use the general operation mode.

4

5

Group No.

Indoor Unit No.

INSTALLATION INSTRUCTIONS

Installer Setting - Setting Address of Central Control

 1,MFL67655412,영어  2017. 11. 9.  오전 11:23  페이지 15

Содержание TM Series

Страница 1: ...nstalling the product Installation work must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly Copyright 2017 LG Electronics Inc All Rights Reserved ESPAÑOL PORTUGUÊS ENGLISH 1 MFL67655412 영어 2017 11 9 오전 11 23 페이지 1 ...

Страница 2: ... is used for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weaken the cooling dehumidifying functions For your records Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes Write the model number and the serial number here Model number Serial number You can find them...

Страница 3: ...e or repair the product There is risk of fire or electric shock Always ground the product There is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire or electric shock Always install a dedicated circuit and breaker Improper wiring or installation may cause fire or elec tric shock Use the correctly rated breaker or fuse There is risk of fire...

Страница 4: ... ventilation before turn the prod uct on Do not use the telephone or turn switches on or off There is risk of explosion or fire If strange sounds or small or smoke comes from product Turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Stop operation and close the window in storm or hurricane If possible remove the product from the window before the hur...

Страница 5: ... plastic parts of the product Do not touch the metal parts of the product when removing the air filter They are very sharp There is risk of personal injury Do not step on or put anyting on the product outdoor units There is risk of personal injury and fail ure of product Always insert the filter securely Clean the filter every two weeks or more often if necessary A dirty filter reduces the efficie...

Страница 6: ...rain Piping 10 Wiring Connection 12 INSTALLATION OF DEC ORATIVE PANEL ACCESSORY 14 TEST RUNNING 15 INSTALLATION INSTRUCTIONS 15 Installer Setting Setting Address of Central Control 15 Installer Setting Checking Address of Central Control 16 Installer Setting How to enter installer setting mode TABLE OF CONTENTS 1 MFL67655412 영어 2017 11 9 오전 11 23 페이지 6 ...

Страница 7: ...ated by arrows from the wall ceiling or other obstacles The indoor unit must keep the maintenance space Unit mm Ceiling Ceiling Board Ceiling Board 300 or more Above 250 1 000 or less 1 000 or more 500 or more 500 or more 300 or less Floor Please use an annexed sheet or the corru gated cardboard on the bottom of packing as installation sheet When using the bottom sheet please use it after separati...

Страница 8: ...es as restaurants and kitchen where considerable amount of oil steam and flour is generated These may cause heat exchange efficiency reduction or water drops drain pump mal function In these cases take the following actions Make sure that ventilation fan is enough to cover all noxious gases from this place Ensure enough distance from the cook ing room to install the air conditioner in such a place...

Страница 9: ...l the piping hole on the wall slightly tilted to the outdoor side using a Ø 70 hole core drill Wall Indoor Outdoor 5 7 mm CAUTION Tighten the nut and bolt to prevent unit falling Maintenance drain port Upward routing not allowed Pipe clamp Indoor unit 300 mm or less Indoor Unit Drain Piping Drain piping must have down slope 1 50 to 1 100 be sure not to provide up and down slope to prevent reversal...

Страница 10: ...this case add heat insulation mate rial according to the following procedure Heat insulation material to be prepared Adiabatic EPDM or NBR with thickness 10 to 20 mm Stick glass wool on all air conditioners that are located in ceiling atmosphere HEAT INSULATION Use the heat insulation material for the refrigerant piping which has an excellent heat resistance over 120 C Precautions in high humidity...

Страница 11: ...connected to the unit should be selected according to the fol lowing specifications If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer of its service agent NORMAL CROSS SECTIONAL AREA 0 75 mm2 20 mm 35 5 mm GN YL 10 3 mm Power wire r Round pressure terminal Connect same thickness wiring to both sides It is forbidden to connect two to one...

Страница 12: ...the panel on the unit by inserting hooks as shown in picture 5 Fit the corner covers 4 Insert two screws on diagonal corners of panel Do not tighten the bolts completely The fixing screws are included in the indoor unit box Check the alignment of panel with the ceil ing Height can be adjusted using hanging bolts as shown in picture Insert the other two screws and tighten all screws com pletely Hoo...

Страница 13: ... CN VANE 1 2 8 Close the cover for control box 9 Install the air inlet grille and Filter on the panel CN VANE 1 2 CN DISPLAY Air conditioner unit Decorative panel Fit the insulator this part and be careful for cool air leakage Good example Ceiling board Ceiling board Decorative panel Air Cool air leakage no good Bad example Air conditioner unit CAUTION Install certainly the decorative panel Cool a...

Страница 14: ...check following items Is the circulation of air adequate Is the draining smooth Is the heat insulation complete refrigerant and drain piping Is there any leakage of refrigerant Is the remote controller switch operated Is there any faulty wiring Are not terminal screws loosened M4 118 N cm 12 kgf cm M5 196 N cm 20 kgf cm M6 245 N cm 25 kgf cm M8 588 N cm 60 kgf cm To cancel the test run press any b...

Страница 15: ...2 Reset the remote controller to use the general operation mode 3 By using the TEMPERATURE SETTING button set the indoor unit address Setting range 00 FF 2 After setting the address press the ON OFF button toward the indoor unit 1 time 3 The indoor unit will display the set address to complete the address set ting The address display time and method can differ by the indoor uint type Reset the rem...

Страница 16: ...hange that is carried out by a non certificated person should be responsible for the results In this case free service cannot be provided With the FAN SPEED button pressed press the RESET button 1 By using the TEMPERATURE SETTING button set function code and setting value Please refer the Installer Setting Code Table 2 Press the ON OFF button toward the indoor unit 1 time 3 Reset the remote contro...

Страница 17: ... product turn off the power then turn it back on after 1 minute Auxiliary heater This function is only applied to models with Auxiliary Heater function being activated No Function Function Code Setting Value Remote Controller LCD 0 Mode Override 0 0 Set to Master 1 Set to Slave 1 Ceiling Height Selection 1 1 Standard 2 Low 3 High 4 Super High 2 Group Control 2 0 Set to Master 1 Set to Slave 2 Chec...

Страница 18: ...18 ENGLISH 1 MFL67655412 영어 2017 11 9 오전 11 23 페이지 18 ...

Страница 19: ...io ambiente e à saúde humana 2 A LG criou o Programa Coleta Inteligente para facilitar e viabilizar o descarte ade quado de parelhos celulares pilhas e baterias 3 Através do Programa Coleta Inteligente a LG disponíbiliza pontos de coleta em localidades diversas incluindo assistências técnicas autorizadas da LG Electron ics Para mais informações visite o site www lge com br coleta seletivaou contat...