18
Electrical Requirements for Electric Models Only
•
This dryer must be connected to a grounded
metal, permanent wiring system, or an
equipment- rounding conductor must be run
with the circuit conductors and connected
to the equipment-grounding terminal or lead
on the dryer.
Failure to do so can result in fire,
explosion, or death.
•
The dryer has its own terminal block that
must be connected to a separate 240 VAC,
60-Hertz, single-phase circuit, fused at 30
amperes (the circuit must be fused on both
sidesoftheline).ELECTRICALSERVICE
FORTHEDRYERSHOULDBEOFTHE
MAXIMUMRATEVOLTAGELISTEDONTHE
NAMEPLATE. DO NOT CONNECT DRYER TO
110-, 115-, OR 120-VOLT CIRCUIT. Heating
elements are available for field installation
in dryers which are to be connected to an
electrical service of a different voltage than
that listed on the rating plate.
Failure to follow
these instructions can result in fire, explosion,
or death.
•
If branch circuit to dryer is 15 ft. (4.5 m)
or less in length, use UL (Underwriters
Laboratories) listed No.-10 AWG wire
(copper wire only), or as required by local
codes. If over 15 ft. (4.50 m), use UL-listed
No.-8 AWG wire (copper wire only), or as
required by local codes. Allow sufficient
slack in wiring so dryer can be moved from
its normal location when necessary.
Failure
to do so can result in fire, explosion, or death.
•
The power cord (pigtail) connection between
wall receptacle and dryer terminal block
ISNOTsuppliedwithdryer.Typeofpigtail
and gauge of wire must conform to local
codes and with instructions on the following
pages.
Failure to follow these instructions can
result in fire, explosion, or death.
•
A 4-wire connection is required for all mobile
and manufactured home installations, as
well as all new construction after January
1, 1996. A 4-wire connection must be used
where local codes do not permit grounding
through the neutral wire.
Failure to do so can
result in fire, explosion, or death.
Special Electrical Requirements for Mobile or Manufactured Homes
• Any installation in a manufactured or mobile
home must comply with the Manufactured
Home Construction and Safety Standards
Title 24 CFR, Part 32-80 or Standard CAN/
CSA0Z240 MH and local codes and ordinances.
•
A 4-wire connection is required for all mobile
and manufactured home installations, as well
as all new construction after January 1, 1996.
Failure to do so can result in fire, explosion, or
death.
CONNECTING ELECTRIC DRYERS
w
WARNING:
To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
w
WARNING:
To help prevent fire, electric shock, serious injury or death, the wiring and
grounding must conform to the latest edition of the National Electrical Code, ANSI/NFPA 70 and all
applicable local regulations. Please contact a qualified electrician to check your home’s wiring and
fuses to ensure that your home has adequate electrical power to operate the dryer.
w
WARNING:
To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
MFL62512825_EN_100524.indd 18
5/24/10 9:38:31 AM
Содержание TDD15515S
Страница 81: ...MFL62512825_SP_100520 indd 41 5 24 10 9 37 16 AM ...
Страница 82: ...MFL62512825_SP_100520 indd 42 5 24 10 9 37 16 AM ...
Страница 83: ...MFL62512825_SP_100520 indd 43 5 24 10 9 37 16 AM ...
Страница 84: ...MFL62512825_SP_100520 indd 44 5 24 10 9 37 16 AM ...