Capacity(Btu/h)
1Phase
3Phase
-
-
-
H
SI
L
G
N
E
Outdoor
Indoor
Main terminal board
Control terminal board
Cord
clamper
Cover control
Main
power source
Switch box
Circuit Breaker
ELECTRICAL WIRING
INDOOR UNIT
• Remove the control box cover for
electrical connection between the
indoor and outdoor unit.(Remove two
screws
➀
.)
• Use the cord clamper to fix the cord.
Perform the electrical wiring work according to
the electrical wiring connection.
• All wiring must comply with local
requirements.
• Select a power source that is capable of
supplying the current required by the air
conditioner.
• Use a recognized circuit breaker
between the power source and the unit.
A disconnection device to adequately
disconnect all supply lines must be
fitted.
• Capacity of circuit breaker
WIRING CONNECTION
OUTDOOR UNIT
• Remove the control cover for wiring
connection.
• Use the cord clamper to fix the cord.
• Earthing work
Connect the cable of diameter 1.6mm
2
or more to the earthing terminal
provided in the control box and do
earthing.
Please check !!
Cover control
Liquid
Gas
Nut
Nut
hexagon wrench
8K/9K
12K
18K
24K
42K
10A
16A
20A
25A
25A
-
-