2. Function of Ice Maker
2-1. Initial Control Function
1. When power is initially applied or reapplied after power cut, it detects level of ice maker cube mould after completion of
MICOM initialization. The detecting lever moves up and down.
2. The level of ice maker cube mould is judged by output signal, high and low signal, of Hall IC. Make the cube mould to be
horizontal by rotating ice ejection motor in normal or reverse direction so that High/Low signal can be applied to MICOM
Pin No. 42.
3. If there is no change in signals one minute after the geared motor starts to operate, it stops icemaker operation and check
the signal every hour. It resets initialization of icemaker when it becomes normal.
4. It judges that the initial control is completed when it judges the ice maker cube mould is horizontal.
5. Ice ejection conducts for 1 cycle irrespect of ice in the ice bank when power is initially applied.
2-2. Water Supply Control Function
1. This is to supply water into the ice maker cube mould by operating water valve in the machine room when ice ejection
control is completed and ice maker mould is even.
2. The quantity of water supplied is determined by DIP switch and time.
<Water Supply Quantity Table>
3. If water supply quantity setting is changed while power is on, water supplies for the amended time. If DIP switch is
changed during water supply, water shall be supplied for the previous setting time. But it will supply for the amended time
from the next supply.
4. When water supply signal is applied to water and ice valves at the same time during water supply, water shall be supplied
to water valve. If water supply signal is applied to ice valve during water supply, water shall be supplied to both water and
ice valves.
2-3. Ice Making Control Function
1. Ice making control is carried out from the completion of water supply to the completion of ice making in the cube mould.
Ice making sensor detects the temperature of cube mould and completes ice making. (ice making sensor is fixed below
ice maker cube mould)
2. Ice making control starts after completion of water supply control or initial control.
3. It is judged that ice making is completed when ice making sensor temperature reaches at -8°C after 100 minutes when
water is supplied to ice maker cube mould.
4. It is judged that ice making is completed when ice maker sensor temperature reaches below -12 °C after 20 minutes in
condition 3.
ICE MAKER AND DISPENSER OPERATION PRINCIPLE AND REPAIR METHOD
- 66 -
DIP SWITCH SETTING
No
S/W 1
S/W 2
S/W 3
WATER SUPPLY TIME
REMARKS
1
OFF
OFF
OFF
6.5 Sec.
2
ON
OFF
OFF
5.5 Sec.
3
OFF
ON
OFF
6 Sec.
4
ON
ON
OFF
7 Sec.
5
OFF
OFF
ON
7.5 Sec.
6
ON
OFF
ON
8 Sec.
7
OFF
ON
ON
9 Sec.
8
ON
ON
ON
10 Sec.
* The quantity of water supplied
depends on DIP switch setting
conditions and water pressure as it is
a direct tap water connection type.
(the water supplied is generally 80 cc
to 120 cc)
* DIP switch is on the main PWB.
Содержание SxS GR-L207MSU
Страница 44: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 44 a b c d ...
Страница 52: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 52 ...
Страница 53: ...3 2 Parts list 1 GR P247 L247 P207 L207 EXPLATION FOR MICOM CIRCUIT 53 ...
Страница 54: ...EXPLATION FOR MICOM CIRCUIT 54 ...
Страница 55: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 55 ...
Страница 56: ...EXPLATION FOR MICOM CIRCUIT 56 ...
Страница 58: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 58 DOUBLE SIDE TAPE SPREAD SHEET ...
Страница 60: ...2 GR C247 B247 C207 B207 60 Reception Transmission Parts without mark means SMD parts ...
Страница 62: ...EXPLATION FOR MICOM CIRCUIT 62 PCB ASSEMBLY DISPLAY PCB ASSEMBLY MAGIC DISPLAY ...
Страница 63: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 63 ...
Страница 64: ...EXPLATION FOR MICOM CIRCUIT 64 PCB ASSEMBLY DISPLAY PCB ASSEMBLY MAGIC DISPLAY ...
Страница 71: ...CIRCUIT 71 ...
Страница 72: ...CIRCUIT 72 ...
Страница 126: ...P No 3828JD8694A JUL 2004 Printed in Korea ...