![LG Studio LSCE365ST Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/lg/studio-lsce365st/studio-lsce365st_service-manual_209752070.webp)
- 70 -
COMPONENT TEST
1. Refer to page 3-4 for the servicing procedure
2. Set the Multiple meter scale to the R x1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (E1 & 1A)
and (E2 & 1A) the meter should indicate :
- (E2 & 1A)
36.0
Ω
± 10%
- (E1 & 1A)
41.1
Ω
± 10%
5. Touch the ohmmeter test leads to limiter
terminals 1A and 2A.the meter should indicate
continuity (0
Ω
)
6. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below (150˚F/65.5˚C), the
meter should indicate an open circuit(infinite).
With the temperature above (150˚F/65.5˚C), the
meter should indicate continuity (0
Ω
).
Dual surface element
: Right Front(RF)
Components
Test procedures
Results
Normal: Approximately 36
Ω
Normal: Approximately 41.1
Ω
Normal: continuity
(below 0.5
Ω
)
If not replace
<Normal>
Below (150˚F/65.5˚C)
open circuit (infinite).
Above (150˚F/65.5˚C)
continuity (0
Ω
)
If not replace
1A
E1
E2
2A
1A
2B
1B
LGE Internal Use Only
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Содержание Studio LSCE365ST
Страница 79: ......