background image

BATTERY LOW WARNING

•  Repeated beeping during an opening indicates that the battery is low and needs immediate replacement. LA GARD

recommends the replacement of batteries at least once annually.

•  Uses one (1) 9-Volt Alkaline Battery. LA GARD recommends the use of Duracell

TM

or Eveready

TM

Alkaline batteries. LA

GARD recommends the replacement of batteries at least once annually.

If battery is depleted and will not allow lock to open, simply follow instructions below. Lock contains a non-volatile
memory, even with batteries removed the lock will retain all programming.

WRONG TRY PENALTY

•  Entry of four (4) consecutive invalid codes starts a 5-minute delay period.

- LED flashes red at ten (10) second intervals.

•  At the end of the delay period, two more consecutive invalid codes will restart an additional 5-minute delay period.

Entry will not respond to a single keystroke during delay period.

REMOVE USER

(Manager feature only.)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1

Enter Manager code and HOLD DOWN LAST DIGIT of CODE until the lock signals with two sets of double beeps.

2

PRESS 3. Lock signals once.

3

User is permanently removed.

4

If a mistake is made wait thirty (30) seconds and repeat steps 

1

3

.

•  Valid Code Entry

- Double signal after valid six (6) digit code is entered.

•  Invalid Code Entry

- Triple signal and old code is still valid.

REINSTATE USER 

(Manager feature only.)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1

Enter Manager code and HOLD DOWN LAST DIGIT of CODE until the lock signals with two sets of double beeps.

2

PRESS 1. Lock signals once.

3

User is reinstated.

4

If a mistake is made wait thirty (30) seconds and repeat steps 

1

3

.

•  Valid Code Entry

- Double signal after valid six (6) digit code is entered.

•  Invalid Code Entry

- Triple signal and old code is still valid.

DUAL CODE OPERATION

(If  feature is active. Must be programmed using 3045 Hand-Held Programmer)

1

Must add second user to open lock. (See 

ADD USER

)  

•  Second User cannot be disabled or removed.

2

If Time Delay is active, one valid code will start Delay period.

•  Both codes required to open lock in Open period.

TIME DELAY 

(If feature is active. Must be programmed using 3045 Hand-Held Programmer.)

1

Enter valid code.

•  Delay period starts.
•  LED flashes RED at one (1) second intervals.

- If valid code entered during delay, Delay period restarts.
- If invalid codes entered during delay, Delay period aborts.

2

At end of delay period, Open period starts.

•  LED flashes RED at 1/2 second intervals.
•  Lock beeps at ten (10) second intervals.

3

During open period, enter valid code(s).

•  If invalid code entered during open, Open period continues.
•  If four (4) consecutive invalid codes entered Wrong Try Penalty starts.

TIME DELAY OVERRIDE

(If  feature is active. Must be programmed using 3045 Hand-Held Programmer)

•  Must add second code. (See 

ADD USER

)

- Second User cannot be disabled or removed.

•  Entry of Override code during Delay period will open the lock.

SILENT SIGNAL ALARM

(If feature is active AND optional Alarm Box is connected to an alarm system.)

•  Enter last digit of code one number higher or one number lower.

Example:

Code:

1-2-3-4-5-6

Duress: 1-2-3-4-5-5  or  1-2-3-4-5-7

•  The lock will open without any indication that the duress signal has been sent.

© copyright 2006

12-223v3

LA GARD INC - A Member of The Kaba Group

Отзывы: