16
ADVANCED FUNCTIONS
ENG
ENGLISH
OPERATING THE AIR CONDITIONER
WITHOUT THE REMOTE CONTROL
RESTARTING THE AIR CONDITIONER
AUTOMATICALLY
DISABLING AUTO RESTART
you can use the on/off button of the indoor unit
to operation the air conditioner when the remote
control is unavailable. However, the fan speed is
set to high.
1. Open the front cover.
- Lift up both side of the cover slightly.
When the air conditioner is turned on again after
a power failure, this function restores the previous
settings. This function is a factory default setting.
1. Open the front cover.
- Lift up both side of the cover slightly.
*The feature can be changed according a type
of model.
2. press the On/Off button and hold it for 6 seconds.
- The unit will beep twice and the lamp will blink
twice 4 times.
*The feature can be changed according a type
of model.
- To re-enable the function, press the On/Off button
and hold it for 6 seconds. The unit will beep twice
and the lamp will blink 4 times.
*The feature can be changed according a type
of model.
2. press the On/Off button.
*The feature can be changed according a type
of model.
- For cooling and heating model, the operation mode
changes, depending on the room temperature.
NOTE
• If you press and hold the On/Off button for 3-5
seconds, the unit will switch to the test operation.
In the test operation, the unit blows out strong
air for cooling for 18 minutes and then returns
to the factory default setting.
!
On/Off
button
On/Off
button
- For cooling only model, the temperature is set
to 22°C.
Room Temp.
Set Temp.
Operation mode
Below 21°C
24°C
Heating operation
Above 21°C
and below
24°C
23°C
Dehumidifying
operation
Above 24°C
22°C
Cooling operation