- 6 -
1. Application range
This specification is applied to ML-041A chassis.
2. Requirement for Test
Testing for standard of each part must be followed in below
condition.
(1) Temperature: 25°C ± 2°C
(2) Humidity: 65% ± 10%
(3) Power: Standard input voltage (AC 100-240V, 50/60Hz)
(4) Measurement must be performed after heat-run more than
30min.
(5) Adjusting standard for this chassis is followed a special
standard.
SPECIFICATION
NOTE : Specifications and others are subject to change without notice for improvement.
3.General Specification(TV)
No
Item
Specification
Remark
1.
Video input applicable system
PAL-D/K, B/G, I, NTSC-M, SECAM
NTSC 4.43
2.
Receivable Broadcasting System
1) PAL/SECAM BG
(RZ/RT)
2) PAL/SECAM DK
EU/Non-EU
3) PAL I/I
(PAL Market)
4) SECAM L/L'
5) NTSC M
6) PAL-N/M
6),7) South America Market
7) NTSC M
7) Except South America NTSC Market (RM)
3.
RF Input Channel
VHF : E2 ~ E12
UHF : E21 ~ E69
PAL
CATV : S1 ~ S20
HYPER : S21~ S41
L/L' : B, C, D
FRANCE
VHF : 2~13
UHF : 14~69
NTSC
CATV : 1~125
VHF Low : 1 ~ M10
JAPAN
VHF High : 4~S22
UHF : S23~62
4.
Input Voltage
AC 100 ~ 240 V/50Hz, 60Hz
5.
Market
Worldwide
6.
Picture Size
584.4 mm
23 inch
7.
Tuning System
FVS 100 program
PAL,200 PR.(Option)
FS
NTSC
8.
Operating Environment
1) Temp : 0 ~ 40 deg
2) Humidity : 85 %
9.
Storage Environment
3) Temp : -20 ~ 60 deg
4) Humidity : 85 %
10.
Display
LCD Module
LPL
Содержание RT-23LZ55
Страница 20: ...BLOCK DIAGRAM RZ 23LZ55 20 ...
Страница 21: ... 21 BLOCK DIAGRAM RT 23LZ55 ...
Страница 24: ... 24 EXPLODED VIEW 010 020 070 100 110 120 130 140 150 160 190 090 080 030 040 050 060 170 180 ...
Страница 37: ......
Страница 38: ......
Страница 39: ...Aug 2005 Printed in Korea P NO 38289S0004V ...