10
Installation
Connection
Precautions
•
Be sure to switch off the unit before installation and connection.
•
The installation should be made by qualified service personnel or
system installers.
•
Do not expose the power and connection cables to moisture, which
may cause damage to the unit.
Connecting Network
You can control and monitor the system via network. With the remote
control (monitoring), you can change the system configuration or monitor
the image via network. After the installation, check the network settings
for the remote control and monitoring work.
Connect the IP camera to your network using a standard RJ-45 network
cable as shown below.
Broadband
Service
Connecting Power Source
Connect power, using one of the methods listed below:
To use the power adapter
Connect AC 24 V power source to the power input terminal as shown
below. (recommended power adapter is AC 24 V / 3 A or above).
A
B
C
No.
Description
Color
A
AC 24 V 1
RED
B
YELLOW GREEN
C
AC 24 V 2
GREEN
Connecting Microphone and Speaker Device
Optionally connect an active speaker and/or external microphone with
a built-in amplifier.
AUDIO IN
GND
AUDIO OUT
Note:
Keep the microphone away from the speaker to avoid howling.
Color
Description
PURPLE
AUDIO IN
BROWN
AUDIO OUT
GREEN
GND
Connecting Alarm Device
Alarm terminals are used to connect the alarm (relay) devices such as
sensors, door switches, etc.
ALARM IN & OUT / ALARM IN & OUT Ret
Connect the sensor device to the sensor input terminal and ground
(GND) terminal. Use the ground (GND) terminal when you need to
connect the sensor device.
Connect the alarm (relay) device to the relay output terminal. Alarm
signal is outputted at an event occurrence.
A
B
C
D
Sensor
Device
ALARM IN
ALARM OUT
Alarm (relay)
Device
No.
Description
Color
A
ALARM IN 1
RED
B
ALARM GND
BLUE
C
ALARM OUT 1
WHITE BROWN
D
ALARM OUT COM
WHITE BLUE