background image

38

PROGRAMMING MODE

3. Time Set Up

Entering set up 
mode.
You will see LqC1

Button

Display

Press the 

Med Temp.

 or the 

Low Temp.

 button until 

 

appears in the display.

Press the 

Start

 button.

The display cycles through 2000 --> 0101 --> Sat --> 0000.

Press the 

Start

 button.

Press 

Med Temp. (+)

 or 

Low Temp.(-)

 button to select year

between 

2000

 and 

2099

.

Press the 

Start

 button.

The machine sets up the year, then advances to the next
process automatically.

Press 

Med Temp. (+)

 or 

Low Temp.(-)

 button to select month

between 

01

 and 

12

.

Press the 

Start

 button.

The machine sets up the month, then advances to the next
process automatically.

Press 

Med Temp. (+)

 or 

Low Temp.(-)

 button to select day

between 

01

 and 

31

.

Press the 

Start

 button.

The machine sets up the day, then advances to the next
process automatically.

Press 

Med Temp. (+)

 or 

Low Temp.(-)

 button to select hour

between 

00

 and 

23

.

Press the 

Start

 button.

The machine sets up the hour, then advances to the next
process automatically.

Press 

Med Temp. (+)

 or 

Low Temp.(-)

 button to select minute

between 

00

 and 

59

.

Press the 

Start

 button.

The machine sets up the minute.

1. Continue to set up the next mode.
2. Stop the change of setup value and go back to ready mode.
     • Coin type - Turn on/off toggle switch.
     • Card type - Pull the service card.
     • Stack type -  1. Control panel open. 

2. Turn on/off toggle switch.

     • OPL/Coin Type - Press “High Temp.” twice.

Содержание RN1329AD1

Страница 1: ...erating your dryer and retain it for future reference MFL62512853 www lg com MODEL RN1329AD1 RV1329AD1 RN1329AD6 RV1329AD6 RN1329AD5S RV1329AD5S RN1329AN4 RV1329AN4 RN1329AN1 RV1329AN1 RN1329AN7S RV1329AN7S RN1329A4 RV1329A4 R N 1 3 2 9 A 1 R V 1 3 2 9 A 1 RN1329A7S RV1329A7S ...

Страница 2: ...n energy saving system ARTISTIC DESIGN Modern front panel look and big clear glass door make your dryer look stylish EASY OF USE An entire selection of user friendly functions makes operating the dryer easy ULTRA CAPACITY The larger drum enables better tumbling and less tangling and wrinkling of the laundry PRODUCT FEATURES ...

Страница 3: ... or discarded remove the door to the drying compartment Do not allow children to play on or in the dryer Close supervision of children is necessary when the dryer is used near children Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubbe...

Страница 4: ...e repair of the products or the replacement of a defective part shall be borne by the owner READ ALL INSTRUCTIONS BEFORE USE wWarning For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage Injury to persons or death WHAT TO DO IF YOU SMELL GAS Applicable for Gas models Do not store or use gasoline or ot...

Страница 5: ...g this appliance follow basic precautions including the following Properly ground dryer to conform with all governing codes and ordinances Follow details in the installation instructions Electric shock can result if the dryer is not properly grounded Before use the dryer must be properly installed as described in this manual Electric shock can result if the dryer is not properly grounded Install a...

Страница 6: ... ductwork locally The end cap should have hinged dampers to prevent backdraft when the dryer is not in use Failure to follow these instructions can result in fire or death The openings must not be obstructed by a carpet Exhaust air must not be discharged into a flue which Is used for exhausting fumes from appliances burning gas or other fuels The exhaust duct must be 4 in 10 cm in diameter with no...

Страница 7: ...cked by a qualified electrician to make sure the outlet is properly grounded Failure to follow these instructions can create an electric shock hazard and or a fire hazard The dryer should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate This provides the best performance and also prevents overloading house wiring circuits which co...

Страница 8: ...3 Top off apply or not setup 23 4 How to enter the special price day setup 24 4 1 How to change sunday 25 5 Special price beginning time setup 26 6 Special price ending time setup 27 7 Regular priced dryer cycle time 28 8 Special priced dryer cycle time 29 9 Value of coin 1 30 10 Value of coin 2 Set up for top off price and e suds coin pulse 31 11 Penny increment pricing offset 32 12 Top off time ...

Страница 9: ...r to the rating label regarding detailed information Single dryer size 686mm W x 764mm D x 983mm H Stack dryer size 686mm W x 764mm D x 1954mm H Capacity 10Kg Weight 59 4 kg Specifications are subject to change by manufacturer Specifications subject to change by manufacturer NOTE ...

Страница 10: ...329AD1 STACK UPPER RN1329AD5S RV1329AD5S STACK LOWER RN1329AD6 RV1329AD6 1 2 4 3 4 1 2 4 3 1 2 4 3 1 2 4 OPL TYPE SIDE BY SIDE RN1329A4 RV1329A4 STACK UPPER RN1329A7S RV1329A7S STACK LOWER RN1329A1 RV1329A1 1 2 4 3 1 DISPLAY LED 2 CYCLE BUTTON 3 START BUTTON 4 STATUS LED ...

Страница 11: ...4 RV1329AN4 3 1 2 4 3 1 2 4 3 1 2 4 3 1 2 4 COIN TYPE STACK UPPER RN1329AN7S RV1329AN7S 3 1 2 4 3 1 2 4 3 1 2 4 3 1 2 4 COIN TYPE STACK LOWER RN1329AN1 RV1329AN1 3 1 2 4 3 1 2 4 3 1 2 4 3 1 2 4 1 DISPLAY LED 2 CYCLE BUTTON 3 START BUTTON 4 STATUS LED ...

Страница 12: ...t Med Temp Use for drying sturdy fabrics such as work casual clothes Medium heat Low Temp Use for drying synthetic fabrics washable knit fabrics and no iron finishes Low heat No Heat Use for items that require heat free drying such as plastics or rubber 3 START BUTTON The Start LED flashes when the full vend price has been satisfied then the cycle has been chosen or the machine is paused The Start...

Страница 13: ... or the chosen course button has been pressed The card should have enough balance to satisfy increasing time The operating time can be increased to 15 minutes 1 00 default by adding more coins When the COOL DOWN has been working if time is added it goes back to the DRYING Time can be added up 99 minutes 5 Change cycle You cannot change the cycle while the machine is running But if the door is open...

Страница 14: ...how How to use button You can change Dryer vend price cycle time and Cycle parameters etc Press button Description High Temp Move to upper level Med Temp Move to the mode in the same level Low Temp Move to the modes in the same level No Heat Start Enter the selected mode If you turn on the power without connecting the meter case for the first time the machine will display When the machine comes fr...

Страница 15: ...ng set up mode 2 Press High Temp button to move the upper level 3 Press Med Temp or Low Temp button if you want to be at the same level 4 Press Start button to enter the details of Set up Diagnostic Tests mode is to set price value time value and vend type etc consists of line test reset free cycle and kill cycle Is to collect the usage data STRUCTURE OF PROGRAMMING MODE Do not use It is only used...

Страница 16: ... Type 1 Push the High Temp and Low Temp button at the same time 2 Push the Med Temp button 3 times 3 Push the Start button 4 Display will show is to set price value time value and vend type etc consists of line test reset free cycle and kill cycle Is to collect the usage data STRUCTURE OF PROGRAMMING MODE Do not use It is only used in inspecting the machine NOTE ...

Страница 17: ... in dryer NOTE Entering set up mode You will see LqC1 Button Display Press the High Temp button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Start button Display previous regular price Press Med Temp or Low Temp button to set regular price The vend price can be set from 0 to 10 00 in 1 increments Press the Start button The machine sets up ...

Страница 18: ...s in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display previous special price Press Med Temp or Low Temp button to set special price The vend price can be set from 0 to 10 00 in 1 increments Press the Start button The machine sets up the regular price then advances to the next process automatically 1 Continue to...

Страница 19: ...s the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Special price days apply or not Disabled Add super wash apply or not Select vend type This function is not available Pre wash apply or not Top off apply or not only for dryer Disable Enable ...

Страница 20: ... the Low Temp button until appears in the display Press the Start button Display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the special price then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready ...

Страница 21: ...d Temp or the Low Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press Med Temp or Low Temp button and then select or Coin type Card type One or the other will display Press the Start but...

Страница 22: ...d Temp or the Low Temp button until appears in the display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the Vend type then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off...

Страница 23: ...tton Display Press the High Temp button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display Structure of Sunday Monday Tuesday Wednesday Thursday Friday Saturday ...

Страница 24: ...appears in the display Press the Start button Display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the special price day Sunday then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type T...

Страница 25: ...the Start button Display previous special price beginning time Press Med Temp or Low Temp button to select time between 0 and 23 Press the Start button The machine sets up the special price beginning time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull th...

Страница 26: ... ending time Press Med Temp or Low Temp button to select time between 1 and 24 Press the Start button The machine sets up the special price ending time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn...

Страница 27: ...tart button Display previous regular priced dryer cycle time Press Med Temp or Low Temp button to select time between 10 and 99 Press the Start button The machine sets up the regular priced dryer cycle time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull ...

Страница 28: ...elect time between 10 and 99 Press the Start button The machine sets up the special priced dryer cycle time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL Coin Type Press Hi...

Страница 29: ...splay previous coin 1 value Press Med Temp or Low Temp button to select value of coin 1 The value can be set fronm 0 to 10 00 in 1 increments Press the Start button The machine sets up the value of coin 1 then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull th...

Страница 30: ...lue can be set fronm 0 to 10 00 in 1 increments Press the Start button The machine sets up the value of coin 2 then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL Coin Type Press...

Страница 31: ... button Display previous penny increment pricing offset Press Med Temp or Low Temp button to select value of PIPo 0 4 Press the Start button The machine sets up the PIPo then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control...

Страница 32: ...Press the Start button Display previous top off time Press Med Temp or Low Temp button to select time between 1 and 30 Press the Start button The machine sets up the top off time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type ...

Страница 33: ...play Press the Start button Display previous value Press Med Temp or Low Temp button to select High or Low or Off Press the Start button The machine sets up the beep volume then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Cont...

Страница 34: ...he display Press the Start button Display previous value Press Med Temp or Low Temp button to select time between 1 180 or Disable Press the Start button The machine sets up the time to keep the coin then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the ser...

Страница 35: ...ering programming mode Insert service card card type Turn on off toggle switch Coin type 2 High Temp Press the High Temp button Then appears in the display 3 Start Enter the diagnostic test mode OPL 1 Entering programming mode Push and hold the High Temp and Low Temp at the same time After that push Med Temp button for 3 times Push Start button 2 High Temp Press the High Temp button Then appears i...

Страница 36: ...AS valve runs Motor Valve Current temperature 5 70 Displays the temperature inside the drum in Celsius 5 time ELECTRIC TYPE Heater runs Motor Heater 1 2250W Heater 2 2250W GAS TYPE GAS valve runs Motor Valve Current temperature 5 70 Displays the temperature inside the drum in Celsius 6 time LED KEY CHECK Press High Temp button Press Med Temp button Press Low Temp button Press No Heat button Versio...

Страница 37: ...y Press the Start button then factory reset is done is displayed 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL Coin Type Press High Temp twice Dryer default value for CARD COIN machine Drying time 45 Minute Top off time ...

Страница 38: ...ances to the next process automatically Press Med Temp or Low Temp button to select day between 01 and 31 Press the Start button The machine sets up the day then advances to the next process automatically Press Med Temp or Low Temp button to select hour between 00 and 23 Press the Start button The machine sets up the hour then advances to the next process automatically Press Med Temp or Low Temp b...

Страница 39: ...ears in the display Press the Start button Press the Med Temp button until appears in the display Press the Start button Display will show Select the course you desire In case of dryer card type it has to insert the cash card after removing the service card Then press the cycle course and the start button It is only applicable to the dryer s card type specially and there is no subtraction in card ...

Страница 40: ... appears in the display Press the Start button Press the Med Temp button until appears in the display Press the Start button Display with beeping Go back to ready mode Insert cycle kill card Descriptions Display Display the current time and Display with beeping Go back to ready mode OPL type Dryer machine will end the cycle by opening the door NOTE ...

Страница 41: ...ble in dryer It can t enter 5 dELC Dryer Moisture Sense dELC is not available in dryer It can t enter 6 ItrC Interval Regular Cycles Number of Regular cycles 0 65535 7 ItCC Interval Regular Cold Cycles ItCC is not available in dryer It can t enter 8 ItAC Interval Regular Warm Cycles ItAC is not available in dryer It can t enter 9 ItHC Interval Regular Hot Cycles ItHC is not available in dryer It c...

Страница 42: ...t available in dryer It can t enter 32 tPdo Time of Previous Service Door Opening tPdo is not available in dryer It can t enter 33 tPCo Time of Previous Coin Vault Opening tPCo is not available in dryer It can t enter 34 SCPr Super Cycle Price Scpr is not available in dryer It can t enter 35 toPr Top Off Price 0 00 10 00 36 Itd Interval Money Amount of money for regular cycle 0 65535 37 ACd Accumu...

Страница 43: ...abrasive cleansers they can scratch or damage the surface Cleaning Around and Under the Dryer Vacuum lint and dust from around the dryer and underneath it regularly Vent ductwork should be checked for lint buildup and cleaned at least once per year If any noticeable reduction in airflow or drying performance occurs immediately check ductwork for obstructions and blockages Maintaining Ductwork Vent...

Страница 44: ...bracket 2 bolt 3 Screw 4 security bracket 1 Stacking bracket 2 Sliding pad 3 Screw The machine can be stacked only on the model designated as suitable by LGE Do not stack the washer on the top You can order the parts for stacking from Qualified dealer or Qualified SVS agent of LGE NOTE Stack type Upper Dryer Lower Dryer Lower Washer Model Name RN1329AD5S RV1329AD5S RN1329AD6S RV1329AD6S F1069FD6 F...

Страница 45: ... of the lower washer in the same position Push the upper dryer matching the slide stacking bracket to make upper and lower front parallel Install the stacking bracket at the rear of the stacked dryer and washer Assemble the six 6 screw to fix the lower machine and upper dryer Security bracket installation Only coin model Install two security bracket on the panel frame and top plate in the lower wa...

Страница 46: ...urrence or problem Dryer error code POWER FAIL RECOVERY In case of power failure the machine stops running but the time display remains on showing the time just before power failure Press the Start button after the power is restored then the machine will restart DEFAULT DRYER SETTINGS Default Settings Default Cycle Time Minutes 45 Minutes Cool Down Time Cycle 2 Minutes High Temperature 154 4 F 68 ...

Страница 47: ...47 ...

Страница 48: ......

Отзывы: