Installation Manual
15
Installation
3. Tape the tubing pipe, drain hose and the connection cable. Be sure that the drain hose is located
at the lowest side of the bundle. Locating at the upper side can cause overflow from the drain pan
through the inside of the unit.
If the drain hose is routed inside the room insulate the hose with an insulation material* so that
dripping from sweating (condensation) will not damage furniture or floors.
* Foamed polyethylene or equivalent is recommended.
Connecting the installation pipe and
drain hose to the indoor unit.
1. Align the center of the pipes and sufficiently
tighten the flare nut by hand
2. Tighten the flare nut with a wrench
3. When needed to extend the drain hose of
indoor unit, assembly the drain pipe as shown
on the drawing
Connecting pipe
Connecting
cable
Tape
Drain hose
mm
inch
kgf.m
Ø6.35
1/4
1.8~2.5
Ø9.52
3/8
3.4~4.2
Ø12.7
1/2
5.5~6.5
Ø15.88
5/8
6.3~8.2
Ø19.05
3/4
9.9~12.1
Outside diameter
Torque
Indoor unit tubing
Flare nut
Pipes
Wrench
Indoor unit tubing
Open-end wrench (fixed)
Connection pipe
Flare nut
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
<Left side piping>
<Right side piping>
Drain hose
Connecting pipe
Connecting
cable
Tape
Drain hose