12
Air Conditioner
Installation
Check
1. Compare the flared work with the figure by.
2. If a flared section is defective, cut it off and
do flaring work again.
Inclined
Inside is shiny without scratches
Smooth all round
Even length
all round
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
Installation of Indoor Unit
1. Hook the indoor unit onto the upper portion of
the installation plate.( engage the three hooks
at the top of the indoor unit with the upper edge
of the installation plate) Ensure that the hooks
are properly seated on the installation plate by
moving it left and right
2. Unlock the tubing holder from the chassis and
mount between the chassis and installation
plate in order to separate the bottom side of the
indoor unit from the wall
Tubing Holder
1
2
Installation plate