5-15
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective PCB
assembly
Replace PCB
assembly
Disconnect the
wire leads from
relay 2 and
check continuity
of relay 2.
(Operate the unit)
Abnormal
Normal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Check high vol-
tage transformer
Normal
Normal
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Check high vol-
tage diode
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check high vol-
tage capacitor
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
Output is full power
when you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective PCB
assembly.
Replace PCB
assembly.
NOTE : • Make sure the wire leads correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Содержание MS3447GR
Страница 27: ...DOOR PARTS 6 2 13552A 13213A 13581A 14970A 14026A 13536A 15006A 13720D 14890A EV ...
Страница 28: ...CONTROL PANEL PARTS 6 3 23572A 23790D 23506A 24781M WTP018 268711 24510L 250201 24970A EV ...
Страница 29: ...OVEN CAVITY PARTS 6 4 33390G WTT010 WTT021 33112U 35889A 36549S WTP013 33052A EV ...
Страница 30: ...LARCH BOARD PARTS 6 5 WSZ085 466001 466003 466001 43500A 43501A EV ...
Страница 32: ...BASE PLATE PARTS 6 7 56170D WSZ002 WTT021 63302A 65006B 63303A 948502 EV ...
Страница 33: ......