5-8
COMPONENT TEST PROCEDURE
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 0.2 ~ 0.4 ohm
Approx.: 70 ~100 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
FILAMENT
WINDING
PRIMARY
TERMINAL
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Содержание MS3447GR
Страница 27: ...DOOR PARTS 6 2 13552A 13213A 13581A 14970A 14026A 13536A 15006A 13720D 14890A EV ...
Страница 28: ...CONTROL PANEL PARTS 6 3 23572A 23790D 23506A 24781M WTP018 268711 24510L 250201 24970A EV ...
Страница 29: ...OVEN CAVITY PARTS 6 4 33390G WTT010 WTT021 33112U 35889A 36549S WTP013 33052A EV ...
Страница 30: ...LARCH BOARD PARTS 6 5 WSZ085 466001 466003 466001 43500A 43501A EV ...
Страница 32: ...BASE PLATE PARTS 6 7 56170D WSZ002 WTT021 63302A 65006B 63303A 948502 EV ...
Страница 33: ......