![LG MS-1902H Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/lg/ms-1902h/ms-1902h_service-manual_1899353024.webp)
5-14
(TROUBLE 3) Output power is low.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 207V.
Normal
Less than 8.5
o
C.
Measure the
magnetron’s
output(See test
procedure).
Faulty magnetron.
Replace.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage
oscillating.
No continuity.
No continuity.
replace.
Malfunction of the
timer switch.
Faulty thermostat.
replace.
Check the
continuity of the
timer switch
contacts.
Check the
continuity of the
thermostat.
1. Oven does not
operate.
No continuity.
No continuity.
Adjust or replace.
Malfunction of the
primary switch.
Malfunction of the
secondary switch.
Adjust or replace.
Check the
continuity of the
primary switch
with door
closed.
Check the
continuity of the
secondary
switch with
secondary
switch pushed.
(TROUBLE 2) Oven does not start even though the timer is set.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Содержание MS-1902H
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 27: ...6 2 13552A 13213A 13581A 13720D 14970A 14026A 13536A 13352A DOOR PARTS ...
Страница 28: ...6 3 24781T 23572A 24510L 250201 24970A 249401 WTP015 26549T CONTROL PANEL PARTS ...
Страница 29: ...6 4 33052M 340511 33112U WTT021 34960A 36549S WTP013 33390G 35889A OVEN CAVITY PARTS ...
Страница 30: ...6 5 43501A 43500A 466002 WSZ085 WTT028 466001 466003 56912B 55262A 969201 WTT028 LATCH BOARD PARTS ...
Страница 32: ...6 7 56170D WTT021 WSZ002 65006B 65006B 50CZZH WSZ002 54810C 56851D 56901A 63302A 63303A BASE PLATE PARTS ...