5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Between Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 1.4
Ω
Approx.: 90
Ω
Less than: 0.1
Ω
Normal:
∞
Normal:
∞
Normal: Less than 1
Ω
Normal:
∞
PRIMARY
TERMINAL
SECONDARY
TERMINAL
FILAMENT
WINDING
TERMINAL
COMPONENT TEST PROCEDURE
Содержание MS-1902H
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 27: ...6 2 13552A 13213A 13581A 13720D 14970A 14026A 13536A 13352A DOOR PARTS ...
Страница 28: ...6 3 24781T 23572A 24510L 250201 24970A 249401 WTP015 26549T CONTROL PANEL PARTS ...
Страница 29: ...6 4 33052M 340511 33112U WTT021 34960A 36549S WTP013 33390G 35889A OVEN CAVITY PARTS ...
Страница 30: ...6 5 43501A 43500A 466002 WSZ085 WTT028 466001 466003 56912B 55262A 969201 WTT028 LATCH BOARD PARTS ...
Страница 32: ...6 7 56170D WTT021 WSZ002 65006B 65006B 50CZZH WSZ002 54810C 56851D 56901A 63302A 63303A BASE PLATE PARTS ...