5-11
COMPONENTS
TEST PROCEDURE
RESULTS
HEATER ELEMENT
(Wire leads removed.)
MAGNETRON
THERMOSTAT
OVEN
THERMOSTAT
FUSE
(Wire leads removed.)
Measure the resistance.
(Multi-meter scale:RX1)
Measure the resistance with 500V-100M
Ohm insulation resistance meter.
Check the continuity of the switch
with an Multi-meter
Normal:
Gill heater
Approx.55
Ω
(at 20-30˚C)
Normal:
more than 0.5M
Ω
NOTE: Make sure heater is fully cooled when tested.
NOTE: If the fuse is blown, check primary, the secondary, the monitor
switches, H.V.D and H.V.C before replacing the fuse.
If the fuse is blown by improper switch operation replace the defective
switch and the fuse at the same time.
Replace just the fuse if the switches operate normally.
0˚C~Approx 150˚C
Approx 150˚C
0˚C~Approx 145˚C
Approx 145˚C
Normal
Abnormal
Содержание MS-1071MC
Страница 29: ...6 2 1002 1003 1008 1004 1000 1005 1006 1007 1001 DOOR PARTS ...
Страница 30: ...6 3 2003 2004 2005 2000 W140 W032 2006 2001 2002 CONTROL PANEL PARTS ...
Страница 31: ...6 4 3006 W101 3023 3002 3021 W081 3014 W094 3024 3025 3013 3020 OVEN CAVITY PARTS ...
Страница 32: ...6 5 4007 W031 4006 W030 4005 4012 4008 W032 4000 4002 4002 4003 4001 4013 4010 4009 SUCTION GUIDE PARTS ...
Страница 33: ...6 6 W067 5001 5002 W067 INTERIOR PARTS ...
Страница 34: ...6 7 W067 W106 6002 6002 6009 6004 6001 6005 6006 6008 6007 W067 W101 BASE PLATE PARTS ...
Страница 35: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 36: ...July 1997 Printed in Korea P NO 3828W5S0547 July 1997 P NO 3828W5S0547 Printed in Korea ...