4. TROUBLE SHOOTING
- 56 -
SETTING : Enter the engineering mode, and set vibrator on at vibration of BB test menu
START
Is the voltage at pin 3
of Q600 high (0.66V)?
YES
NO
Is the voltage at pin 2
of Q600 low (2.3V) ?
YES
Is the voltage at pin 1
of Q600 high (VBAT) ?
YES
Check the soldering
of vibrator ?
YES
Replace vibrator
YES
Vibrator
Working well !
Check the soldering
of R611, R614
NO
Check the soldering
of R604,R609
NO
Check the soldering
of R603, Q600
Resolder or Replace vibrator
NO