Vinyl tape(narrow)
Connecting cable
Pipe
Connection
pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Indoor
unit pipe
Drain pipe
Connecting cable
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
Plastic bands
Insulation material
Tighten the flare nut with a wrench.
Wrap the area which accommodates the rear
piping housing section with vinyl tape.
Capacity
(Btu/h)
Pipe Size[Torque]
GAS
LIQUID
9K, 12K
18K, 24K, 26K
.
.
1/2"[5 5kg m]
.
.
5/8"[6 6kg m]
.
.
1/4"[1 8kg m]
.
.
3/8"[4 2kg m]
Bundle the piping and drain hose together by
wrapping them with vinyl tape over the range
within which they fit into the rear piping
housing section.
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
B
Insert the piping, drain hose and the connecting
cable into the piping hole.
F
Wrap the insulation material around the
connecting portion.
A
Route the indoor tubing and the drain hose to
the required piping hole position.
For right rear piping
When extending the drain hose at the indoor unit,
install the drain pipe.
Overlap the connection pipe insulation material and
the indoor unit pipe insulation material. Bind them
together with vinyl tape so that thee is no gap.
Spanner (fixed)
Flare nut
Connection pipe
Torque wrench
Indoor unit tubing
FLARING WORK AND CONNECTION OF PIPING