background image

8-2

PRINTED CIRCUIT BOARD

KEY P.C.B.

MAIN P.C.B.

Содержание MD-0942GT

Страница 1: ...P NO 3828W5S2388 Website http biz lgservice com July 2002 Printed in Korea MICROWAVE OVEN SERVICE MANUAL MODEL MD 0942GT CAUTION BEFORE SERVICING THE UNIT READ THE SAFETY PRECAUTIONS IN THIS MANUAL ...

Страница 2: ...r and other damage 4 damage to or loosening of hinges and latches 5 evidence of dropping or abuse C Before turning on microwave power for any service test or inspection within the microwave generating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections D Any defective or misadjusted components in the interlock monitor door seal...

Страница 3: ... CIRCUIT DESCRIPTION 4 4 SERVICE INFORMATION 5 1 TOOLS AND MEASURING INSTRUMENTS 5 1 MICROWAVE LEAKAGE TEST 5 1 MEASUREMENT OF MICROWAVE POWER OUTPUT 5 3 DISASSEMBLY AND ADJUSTMENT 5 3 INTERLOCK CONTINUITY TEST 5 7 COMPONENT TEST PROCEDURE 5 8 TROUBLE SHOOTING 5 12 EXPLODED VIEW 6 1 REPLACEMENT PARTS LIST 7 1 SCHEMATIC DIAGRAM OF P C B 8 1 PRINTED CIRCUIT BOARD 8 2 P C B PARTS LIST 9 1 CONTENTS ...

Страница 4: ...5 kg approx 18 kg approx Microwave Power for Variable Cooking Power level MAX Full power throughout the cooking time MED HIGH approx 80 of Full power MEDIUM approx 60 of Full power DEFROST approx 40 of Full power LOW WARM approx 20 of Full power TOAST COMBI Owner s manual Glass turntable Rotating ring 1 1 ITEM MODEL Power Requirement Power Output Microwave Frequency Magnetron Timer Outside Dimensi...

Страница 5: ...tron be assembled to the waveguide and cavity Never operate the magnetron unless it is properly installed Be sure that the magnetron gasket is properly installed around the dome of the tube whenever installing the magnetron 2 1 CAUTIONS Unlike other appliances the microwave oven is high voltage and high current equipment Though it is free from danger in ordinary use extreme care should be taken du...

Страница 6: ...to prevent interference 8 Do not touch the front glass during or after cooking of the Grill and Combination mode This glass is very hot during heater operating 9 Do not operate the oven at microwave and combination mode with Grill rack placed in the cavity when the oven is empty EARTHING INSTRUCTIONS This microwave oven is designed to be used in a fully earthed condition It is imperative therefore...

Страница 7: ...desired time 2 CLOCK Used to set the time of day 3 POWER Used to select the desired power level for cooking 4 AUTO COOK Used to cook the foods listed by one touch 5 AUTO DEFROST Used to select the auto weight defrost 6 STOP CLEAR Used to stop over and clear all entries except time of day 7 START One tap allows over to begin functioning 8 TOAST START STOP Start or stop for toast 9 TOAST COOK TIME U...

Страница 8: ...TWO STAGE COOKING 7 AUTO WEIGHT DEFROST 8 AUTO COOK 9 CHILD LOCK This oven has a CHILD LOCK feature TO SET CHILD LOCK Touch the pad Touch STOP pad L appear in the display TO CANCEL CHILD LOCK Touch the pad touch STOP pad L disappears Parar Borrar Reloj Set the hour Set the minute Inicio Parar Borrar Inicio Parar Borrar Inicio Parar Borrar Desired defrost category Desired cooking time Inicio Parar ...

Страница 9: ...SCHEMATIC DIAGRAM 4 3 BN Fuse ...

Страница 10: ...0 Volts DC is applied to the filament of the magnetron WHEN THE OVEN IS SET AT ANY LEVEL EXCEPT MAXIMUM The micom controller controls the ON OFF time of relay 3 by the applied signal to vary the average output power of microwave oven as POWER LEVEL refer to page 1 1 One complete cycle of relay 3 is 22 seconds WHEN THE DOOR IS OPENED DURING COOKING Both the primary switch and relay 3 are cut off pr...

Страница 11: ...ich is graduated to 600 cc and place the beaker on the center of the turntable Set the energy leakage monitor to 2 450 MHz and use it following the manufacturer s recommended test procedure to assure correct result When measuring the leakage always use the 2 inch 5cm spacer supplied with the probe Operate the oven at its maximum output Measure the microwave radiation using and electromagnetic radi...

Страница 12: ...e test probe must be removed no faster than 1 inch sec 2 5 cm sec along the shaded area otherwise a false reading may result The test probe must be held with the grip portion of the handle A false reading may result if the operator s hand is between the handle and the probe When testing near a corner of the door keep the probe perpendicular to the surface making sure the probe horizontally along t...

Страница 13: ...ture is 5 K The microwave power output P in watts is calculated from the following formula 4187 x T 0 55 X T2 T0 X M T is measured while the microwave generator is operating at full power Magnetron filament heat up time is not included about 3 sec The water is stirred to equalize temperature throughout the vessel prior to measuring the final water temperature Stirring devices and measuring instrum...

Страница 14: ...ORMER REMOVAL 1 Discharge the high voltage capacitor 2 Disconnect the leadwire from magnetron high voltage transformer and capacitor 3 Remove the screw holding the high voltage transformer to the baseplate F FAN MOTOR ASSEMBLY REMOVAL 1 Discharge the high voltage capacitor 2 Disconnect the leadwire from fan motor noise filter and high voltage capacitor 3 Remove the two screws holding the the sucti...

Страница 15: ...5 ml water load Make sure that gasket is rigidly attached to the magnetron To prevent microwave leakage tighten the mounting screws properly making sure there is no gap between the waveguide and the magnetron J REMOVING THE TURNTABLE MOTOR 1 Remove the turntable 2 Remove the turntable shaft VERY CAREFULLY with a slotted screwdriver 3 Lay the unit down on its back 4 Remove the turntable motor cover...

Страница 16: ...ADJUSTMENT OF THE LATCH BOARD TO THE OVEN ASSEMBLY Mount the latch board to the oven assembly Adjust the latch board in the arrow direction so that oven door will not have any play in it when the door is closed Tighten the mounting screw Check for play in the door by pushing the door release button Door movement should be less than 0 5 mm 1 64 inch Don t push the door release button while making a...

Страница 17: ...osed meter should indicate an closed circuit When the secondary switch operation is abnormal make the necessary adjustment or replace the switch only with the same type of switch C MONITOR SWITCH TEST Disconnect the wire lead from the monitor switch Connect the ohmmeter leads to the common COM and normally closed NC terminals of the switch The meter should indicate closed circuit in the door open ...

Страница 18: ... RESULTS HIGH VOLTAGE TRANSFORMER Wire leads removed MAGNETRON Wire leads removed 1 Measure the resistance Ohm meter scale Rx1 and Rx100 Primary winding Secondary winding Filament winding 2 Measure the resistance Ohm meter scale Rx1000 Primary winding to ground Filament winding to ground 1 Measure the resistance Ohm meter scale Rx1 Filament terminal 2 Measure the resistance Ohm meter scale Rx1000 ...

Страница 19: ... Terminal to case Measure the continuity Forward Ohm meter scale Rx10000 Measure the continuity Reverse Ohm meter scale Rx10000 Normal Momentarily indicates several ohms and then gradually returns to infinite Normal Infinite Normal Continuity Abnormal Infinite Normal Infinite Abnormal Continuity NOTE When testing the magnetron be sure to install the magnetron gasket in the correct position and be ...

Страница 20: ...replacing the fuse If the fuse is blown by improper switch operation replace the defective switch and the fuse at the same time Replace just the fuse if the switches operate normally NOTE Make sure heater is fully cooled when tested Measure the resistance Multi meter scale Rx1 Normal Toast heater Approx 95 ohm at 20 30o C Normal more than 0 5 Mohm Normal Abnormal Measure the resistance with 500V 1...

Страница 21: ...he resistance Ohm meter scale R x 1 Measure the resistance Ohm meter scale R x 1000 Normal Approx 200 400 ohm Abnormal Infinite or several ohm Normal Approx 10 20 kohm Abnormal Infinite or several ohm NOTE A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS SERVICED FOR ANY REASON MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION WHEN REMOVING THE WIRE LEADS FROM THE PARTS BE SUR...

Страница 22: ...el to discharge any static charge built up in your body CONDITION Microwave oven does not work Inserting many plug into one plug outlet and using them at the same time causes overloading Microwave oven plug is not inserted tightly Output power is too low Low AC input voltage Food temperature is too low Using metallic ware and allowing it to touch the oven wall Sparks occurring Inconsistent intensi...

Страница 23: ...ing cooking cycle 11 Display time of day does not reappear when cooking is finished 12 Beep sound is not heard when correct key is touched 5 13 TROUBLE 1 The following visual conditions indicate a probable defective control circuit CONDITION CHECK RESULT CAUSE REMEDY 1 No input can be programmed Continuity No continuity Defective PCB assembly Loose connection Replace PCB assembly Connect them tigh...

Страница 24: ...ch with door closed Check continuity of primary switch with door opened Disconnect one side of the wire lead connected from transformer to the high voltage capacitor and operate the unit Replace fuse TROUBLE 2 Oven does not operate at all Display window does not display any figures and no input is accepted NOTE All these switches must be replaced at the same time Refer to page 5 6 5 7 2 Fuse does ...

Страница 25: ...uity of secondary switch with door closed Check fan motor Check oven lamp Abnormal Abnormal Normal Defective fan motor Defective fan motor Replace fan motor Replace fan motor Loose connection Connection then tightly CONDITION CHECK RESULT CAUSE REMEDY Output is low Lower than 90 of rating voltage Normal Normal Abnormal Abnormal Measure the output power Disconnect the wire leads from relay 3 and ch...

Страница 26: ...l Defective high voltage transformer Replace high voltage transformer Check H V transformer normal normal Abnormal Defective high voltage Diode Replace high voltage Diode Check H V diode Abnormal Defective high voltage capacitor Replace high voltage capacitor Check H V capacitor Abnormal Defective magnetron Replace magnetron Check Magnetron TROUBLE 5 No microwave oscillation even though oven lamp ...

Страница 27: ...ction the heater Replace Replace TROUBLE 6 Oven does not cook properly when programmed for the set power level Operates properly on HIGH CONDITION CHECK RESULT CAUSE REMEDY Output is full when you set lower power level Abnormal Disconnect the wire leads from relay 3 and check continuity relay 3 Operate the unit Defective P C B assembly Replace P C B assembly NOTE Make sure the wore leads correct p...

Страница 28: ...INTERIOR PARTS OVEN CAVITY PARTS DOOR PARTS TOAST PARTS BASE PLATE PARTS LATCH BOARD PARTS CONTROL PANEL PARTS 6 1 EXPLODED VIEW INTRODUCTION EV ...

Страница 29: ...6 2 13650A 13720D 13352A 13213A 14026A 13552A 15006A 13536A 14970A 13581A DOOR PARTS EV ...

Страница 30: ...6 3 23506A 13352A 268712 WTP004 CONTROL PANEL PARTS EV ...

Страница 31: ...6 4 33112U WTT020 WTT021 WTP013 36549S 33390G 34370T 34036W 948503 35889A 33052A OVEN CAVITY PARTS EV ...

Страница 32: ...6 5 WSZ085 WTT028 56912B 55262A 44510A 466001 43500A 43501A 466003 466001 LATCH BOARD PARTS EV ...

Страница 33: ...6 6 568771 WSZ002 WSZ002 WTT028 56411A 56930V 56549F 54974S WTT037 55900A 268711 56324A 54810C WTT028 50CZZH 50FZZA WSZ002 WSZ002 56851D WTP004 55006F INTERIOR PARTS EV ...

Страница 34: ...6 7 WTT021 63302A 63303A 56170D WSZ002 WTT028 WSZ002 647781 65006A BASE PLATE PARTS EV ...

Страница 35: ...6 8 743501 73720D 73213A 75993M 73352A 73550D 73550H 73390M 73740A 73552A 73572A 76930V TOAST PARTS EV ...

Страница 36: ...8 1 SCHEMATIC DIAGRAM OF P C B ...

Страница 37: ...8 2 PRINTED CIRCUIT BOARD KEY P C B MAIN P C B ...

Страница 38: ......

Отзывы: