NECESSARY TOOLS
Tools normally used for TV servicing are sufficient.
Standard tools are listed below.
• Diagonal pliers
• Long nose pliers
• Cross head screwdriver
• Wrench (size 5 mm)
• Nutdriver (size 5 mm)
• Adjustable wrench
• Soldering iron
• Solder
• Vinyl insulation tape
• Polishing cloth
CAUTIONS
• Be sure to check a microwave emission prior to
servicing the oven if the oven is operative prior to
servicing.
• If the oven operates with door open, the service
personnel should;
—Tell the user not to operate the oven
• The service personnel should check all surface and
vent openings for microwave emission testing.
• Check for microwave energy leakage after every
servicing. The power density of the microwave
radiation leakage emitted by the microwave oven
should not exceed 4 mW/cm
2
.
And always start measuring of an unknown field to
assure safety for operating personnel from radiation
leakage.
NOTE
: The standard is 5 mW/cm
2
while in the
customer’s home. 4 mW/cm
2
stated here is
manufacturer’s own voluntary standard for units in
customer’s home.
EQUIPMENT
• Microwave Survey Meter
• 600cc glass beaker
• Glass thermometer 100°C
NECESSARY MEASURING
INSTRUMENTS
• TESTER (VOLTS-DC, AC, Multmeter)
• Microwave survey meter
—Holaday H1-1500, Hi-1501
—Narda 8100, 8200
• Inch scale
• 600 cc non conductive material beaker (glass or
plastic), inside diameter: approx. 8.5cm (3
1
/
2
in.)
• Cylindrical and made of borosilicate glass vessel max.
thickness: 3mm
outside diameter: approx. 190mm
height: approx. 90mm
• Glass thermometer: 100°C or 212°F (1 deg scale)
MEASURING MICROWAVE ENERGY
LEAKAGE
• Pour 275 ± 15cc of 20°C ± 5°C water in a beaker which
is graduated to 600 cc, and place the beaker on the
center of the turntable.
• Set the energy leakage monitor to 2,450 MHz and use
it following the manufacturer’s recommended test
procedure to assure correct result.
• When measuring the leakage, always use the 2 inch
(5cm) spacer supplied with the probe.
• Operate the oven at its maximum output.
• Measure the microwave radiation using and
electromagnetic radiation monitor by holding the probe
perpendicular to the surface being measured.
Tools and Measuring Instruments
5-1
Microwave Leakage Test
SERVICE INFORMATION
Move probe along shaded area.
Probe scanning speed;
Less than 2.5 cm/sec
Содержание MC-806CLR
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 31: ...DOOR PARTS 6 2 NSP 13350F 13581A 14970A 14026A 13552A 15006A 13213A 14890A ...
Страница 32: ...CONTROL PANEL PARTS 6 3 WTP004 268711 268712 23790D NSP 24781S 250203 250201 250202 24970A 24510L 23550F ...
Страница 34: ...LATCH BOARD PARTS 6 5 WSZ085 466002 43501A 466003 466001 43500A ...
Страница 36: ...BASE PLATE PARTS 6 7 WSZ062 WSZ002 WTT030 948505 948502 63302A 56170D 647781 63303A 948506 ...
Страница 37: ...SCHEMATIC DIAGRAM OF P C B 8 1 ...
Страница 38: ...PRINTED CIRCUIT BOARD 8 2 ...