5-16
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective P.C.B
assembly
Replace P.C.B
assembly
Disconnect the
wire leads from
relay 2 and
check continuity
of relay2.
(Operate the
unit)
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check H.V.
capacitor.
Abnormal
normal
Defective high
voltage
transformer.
Replace high
voltage
transformer .
Check H.V.
transformer.
Abnormal
Defective high
voltage Diode.
Replace high
voltage Diode.
Check H.V.
diode.
normal
Abnormal
Defective
magnetron.
Replace
magnetron .
Check
Magnetron.
normal
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run
(Display operates properly)