5-15
CONDITION
CHECK
RESULT
CAUSE
REMEDY
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1.Setting time does
not count down
when touching
START pad.
No continuity.
Continuity.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check continuity
of secondary
switch (with
door closed).
2. Fan motor or
oven lamp do
not turn
on.
No continuity.
Defective fan
motor.
Replace fan
motor.
Check fan motor.
No continuity.
Defective oven
lamp.
Replace oven
lamp.
Check oven lamp.
Normal.
No continuity.
Continuity.
Defective P.C.B
assembly.
Replace P.C.B
assembly.
Loose connection.
Connection then
tightly.
Output is low.
Lower than 90% of
rating voltage.
Normal.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
Disconnect the
wire leads from
relay 2 and check
on and off time
with multitester.
Abnormal.
Abnormal.
Abnormal.
Defective
magnetron.
Replace
magnetron.
Defective P.C.B
assembly.
Replace P.C.B
assembly.
Measure the
Abnormal. output.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while
desired program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operation but little heat is produced in oven load.
NOTE: Simple test of power output-conducted by heating one liter water for one min. if available.
Содержание MB-4384B
Страница 29: ...6 2 13552A 14890A 13213A 13720D 14026A 14970A WTT028 13581A 13536A 13650A DOOR PARTS ...
Страница 30: ...6 3 24781S 23572A 23790D 250201 250205 249401 249402 250203 250204 250202 268711 WTP013 CONTROL PANEL PARTS ...
Страница 32: ...6 5 466001 466003 WSZ085 466001 43500A LATCH BOARD PARTS ...
Страница 34: ...6 7 56170D 63303A WSZ002 WTT021 63302A 65006B BASE PLATE PARTS ...
Страница 35: ......