background image

4-4

CIRCUIT DESCRIPTION

•  As the door is closed, the contact of MONITOR

SWITCH opens. This switch creates the short circuit to
blow fuse during operation under abnormal condition.
(ie, should the contacts of primary and secondary
switch fail to open the circuit)

•  The latches are secured by latch board. The oven light

turns on while the oven is in operation.

WHEN MICROWAVE POWER LEVEL
AND COOKING TIME SET

•  The contacts of the timer switch changes to ON

position when the timer knob is rotated.
(While power control knob is set at “Full Power”)

•  The contacts of primary and secondary switch close

the circuit.

•  Input Volts AC. is applied to the high voltage

transformer through power control switch as shown by
the solid line.

•  Turntable rotates.
•  The fan motor rotates and cools the magnetron by

blowing the air (coming from the intake holes on the
baseplate) over the magnetron.

•  The air is also directed into the oven to exhaust the

vapor in the oven through the upper plate.

•  Timer starts rotating.
•  3.2 volts AC is generated from the filament winding of

the high voltage transformer. This 3.2 volts is applied
to the magnetron to heat the magnetron filament
through two noise preventing choke coils.
A high voltage of approximately 2100 volts AC is
generated in the secondary of the high voltage
transformer which is increased by the action of the
diode and charging of the high voltage capacitor.
The negative DC voltage is then applied to the filament
of the magnetron.

WHEN THE DOOR IS OPENED DURING
COOKING

•  Both primary switch and secondary switch open to cut

off the primary winding voltage to the high voltage
transformer to stop microwave oscillation.

•  Timer, turntable and fan motor stop.
•  As the door is opened, if the contact of primary switch

fail to open, the fuse opens due to the large current
surge caused by the monitor switch activation which in
turn stops magnetron, oscillation.

WHEN THE GRILL COOKING FUNCTION
SELECTED

•  The contacts of the timer switch change to ON

position.

•  The contacts of the grill select switch close the circuit.
•  Input volts AC is applied to the grill heater through

thermostat-grill as shown by the solid line.

•  The fan motor and turntable rotates.

FUSE

PRIMARY

SWITCH

SECONDARY

SWITCH

MONITOR

SWITCH

L

N

H.V.T

TIMER

SWITCH

POWER

CONTROL

SWITCH

FUSE

PRIMARY

SWITCH

SECONDARY

SWITCH

MONITOR

SWITCH

L

N

H.V.T

TIMER

SWITCH

POWER

CONTROL

SWITCH

PRIMARY

SWITCH

TIMER

SWITCH

GRILL

SELECT
SWITCH

L

N

THERMOSTAT

GRILL

GRILL 

HEATER

L

G -Y

N

E

Содержание MB-4022G

Страница 1: ...MICROWAVE OVEN SERVICE MANUAL MODEL MB 4022G CAUTION BEFORE SERVICING THE UNIT READ THE SAFETY PRECAUTIONS IN THIS MANUAL website http biz lgservice com ...

Страница 2: ...r and other damage 4 damage to or loosening of hinges and latches 5 evidence of dropping or abuse C Before turning on microwave power for any service test or inspection within the microwave generating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections D Any defective or misadjusted components in the interlock monitor door seal...

Страница 3: ...TING SEQUENCE 4 2 SCHEMATIC DIAGRAM 4 3 CIRCUIT DESCRIPTION 4 4 SERVICE INFORMATION 5 1 TOOLS AND MEASURING INSTRUMENTS 5 1 MICROWAVE LEAKAGE TEST 5 1 MEASUREMENT OF MICROWAVE POWER OUTPUT 5 3 DISASSEMBLY AND ADJUSTMENT 5 3 INTERLOCK CONTINUITY TEST 5 7 COMPONENT TEST PROCEDURE 5 8 TROUBLE SHOOTING 5 12 EXPLODED VIEW 6 1 REPLACEMENT PARTS LIST 7 1 CONTENTS ...

Страница 4: ... 2M213 240GP 60 Min 455 W x 281 H x 313 D mm 312 W x 203 H x 293 D mm 12 0 kg approx 13 2 kg approx Microwave Power for Variable Cooking Power level Max 500W 350W Defrost 70W Grill Combi 1 2 3 Owner s manual Glass tray Roller Rest Grill rack 1 1 ITEM MODEL Power Requirement Power Output Microwave Frequency Magnetron Timer Outside Dimensions Cavity Dimensions Net Weight Shipping weight Control Comp...

Страница 5: ...tron be assembled to the waveguide and cavity Never operate the magnetron unless it is properly installed Be sure that the magnetron gasket is properly installed around the dome of the tube whenever installing the magnetron 2 1 CAUTIONS Unlike other appliances the microwave oven is high voltage and high current equipment Though it is free from danger in ordinary use extreme care should be taken du...

Страница 6: ...to prevent interference 8 Do not touch the front glass during or after cooking of the Grill and Combination mode This glass is very hot during heater operating 9 Do not operate the oven at microwave and combination mode with Grill rack placed in the cavity when the oven is empty EARTHING INSTRUCTIONS This microwave oven is designed to be used in a fully earthed condition It is imperative therefore...

Страница 7: ...L PANEL Safety Door Lock System Control Panel Window Door Screen Door Seal Oven Front Plate Grill Rack Turntable Roller Rest 1 2 1 POWER CONTROL KNOB Used in selected the desired power level for cooking 2 TIMER KNOB Used to set the cooking time ...

Страница 8: ...the food on the rack in the oven and close the oven door 2 Set the function 3 Set the timer to the desired cooking time The turntable begins to rotate cooking starts and the lamp is turned on At the end of the cooking time you will hear a ring sound and the lamp is turned off COMBI COOKING 1 Open the oven door place the food on the rack in the oven and close the oven door 2 Set the 1 2 3 function ...

Страница 9: ...4 3 SCHEMATIC DIAGRAM ...

Страница 10: ...gnetron filament through two noise preventing choke coils A high voltage of approximately 2100 volts AC is generated in the secondary of the high voltage transformer which is increased by the action of the diode and charging of the high voltage capacitor The negative DC voltage is then applied to the filament of the magnetron WHEN THE DOOR IS OPENED DURING COOKING Both primary switch and secondary...

Страница 11: ...ich is graduated to 600 cc and place the beaker on the center of the turntable Set the energy leakage monitor to 2 450 MHz and use it following the manufacturer s recommended test procedure to assure correct result When measuring the leakage always use the 2 inch 5cm spacer supplied with the probe Operate the oven at its maximum output Measure the microwave radiation using and electromagnetic radi...

Страница 12: ...ter than 1 inch sec 2 5 cm sec along the shaded area otherwise a false reading may result The test probe must be held with the grip portion of the handle A false reading may result if the operator s hand is between the handle and the probe When testing near a corner of the door keep the probe perpendicular to the surface making sure the probe horizontally along the oven surface this may possibly c...

Страница 13: ... final water temperature and the ambient temperature is 5 K The microwave power output P in watts is calculated from the following formula is measured while the microwave generator is operating at full power Magnetron filament heat up time is not included about 3 sec The water is stirred to equalize temperature throughout the vessel prior to measuring the final water temperature Stirring devices a...

Страница 14: ...REMOVAL 1 Discharge the high voltage capacitor 2 Disconnect the leadwire from magnetron high voltage transformer and capacitor 3 Remove the screw holding the high voltage transformer to the baseplate F FAN MOTOR ASSEMBLY REMOVAL 1 Discharge the high voltage capacitor 2 Disconnect the leadwire from fan motor noise filter and high voltage capacitor 3 Remove the two screws holding the the suction gui...

Страница 15: ... cm2 With a 275 ml water load Make sure that gasket is rigidly attached to the magnetron To prevent microwave leakage tighten the mounting screws properly making sure there is no gap between the waveguide and the magnetron J REMOVING THE TURNTABLE MOTOR 1 Remove the turntable 2 Remove the Rotating Ring 3 Lay the unit down on its back 4 Remove the turntable motor cover The turntable base cover is e...

Страница 16: ...EN ASSEMBLY Mount the latch board to the oven assembly Adjust the latch board in the arrow direction so that oven door will not have any play in it when the door is closed Tighten the mounting screw Check for play in the door by pushing the door release button Door movement should be less than 0 5 mm 1 64 inch Don t push the door release button while making adjustment Make sure that the latch move...

Страница 17: ... closed meter should indicate an closed circuit When the secondary switch operation is abnormal make the necessary adjustment or replace the switch only with the same type of switch C MONITOR SWITCH TEST Disconnect the wire lead from the monitor switch Connect the ohmmeter leads to the common COM and normally closed NC terminals of the switch The meter should indicate closed circuit in the door op...

Страница 18: ...NT TEST PROCEDURE COMPONENTS TEST PROCEDURE RESULTS HIGH VOLTAGE TRANSFORMER Wire leads removed MAGNETRON Wire leads removed 1 Measure the resistance Ohm meter scale Rx1 Primary winding Secondary winding Filament winding 2 Measure the resistance Ohm meter scale Rx1000 Primary winding to ground Filament winding to ground 1 Measure the resistance Ohm meter scale Rx1 Between Filament terminal 2 Measu...

Страница 19: ...r scale Rx1000 Terminal to case Measure the continuity Forward Ohm meter scale Rx10000 Measure the continuity Reverse Ohm meter scale Rx10000 Normal Momentarily indicates several ohms and then gradually returns to infinite Normal Normal Abnormal Continuity Normal Continuity Abnormal NOTE When testing the magnetron be sure to install the magnetron gasket in the correct position and be sure that the...

Страница 20: ...is blown by improper switch operation replace the defective switch and the fuse at the same time Replace just the fuse if the switches operate normally Check for continuity of the H V Fuse with multi meter NOTE Make sure heater is fully cooled when tested Measure the resistance Multi meter scale Rx1 Normal Grill heater Approx 38 ohm at 20 30o C Normal more than 0 5 Mohm Normal Abnormal Measure the...

Страница 21: ...NOTE A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS SERVICED FOR ANY REASON MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION WHEN REMOVING THE WIRE LEADS FROM THE PARTS BE SURE TO GRASP THE CONNECTOR NOT THE WIRES C 2 3 B 2 M A 1 2 A B C A Turn on Approx 250Ω Turn Off B FAN MOTOR Wire leads removed TURNTABLE MOTOR Wire leads removed Normal Abnormal or several Ω Normal Appro...

Страница 22: ...oading Microwave oven plug is not inserted tightly Output power is too low Low AC input voltage Food temperature is too low Using metallic ware and allowing it to touch the oven wall Sparks occur Inconsistent intensity of microwave by their characteristics 1 Use plastic wrap or lid 2 Stir once or twice while cooking soup cocoa or milk etc Uneven cooking Ceramic ware trimmed in gold or silver powde...

Страница 23: ...ned Disconnect one side of the wire lead connected from transformer to the high voltage capacitor and operate the unit Replace fuse 1 Oven does not operate No continuity No continuity Adjust or replace Malfunction of the primary switch Malfunction of the secondary switch Adjust or replace Check the continuity of the primary switch with door closed Check the continuity of the secondary switch with ...

Страница 24: ...ician Check the power source voltage oscillating No continuity No continuity replace Malfunction of the timer switch Faulty thermostat replace Check the continuity of the timer switch contacts Check the continuity of the thermostat CONDITION CHECK RESULT CAUSE REMEDY TROUBLE 4 Grill CONDITION CHECK RESULT CAUSE REMEDY 1 Heater is not operating Abnormal Normal Normal Heater Thermostat Grill Abnorma...

Страница 25: ...nitor resistor Abnormal Defective AC relay Replace Normal Check the AC relay Abnormal Open the secondary winding of the high voltage transformer of faulty insulation of filament winding Replace Check H V transformer Abnormal Shorted H V diode Replace Check H V diode Abnormal Faulty capacitor Replace Check H V capacitor Abnormal Faulty magnetron Replace Magnetron Abnormal Faulty H V Fuse Replace Ch...

Страница 26: ...6 1 EXPLODED VIEW INTRODUCTION ...

Страница 27: ...6 2 13581A 14970A 14026A 13552A 13536A 13213A 14890A 13720D DOOR PARTS ...

Страница 28: ...6 3 24781T 26549T WTT021 249401 23572A 368771 249402 CONTROL PANEL PARTS ...

Страница 29: ...6 4 WTT010 WTT021 WTT021 33112U 33550H 35264A 33052M WTP013 WSZ184 35300S 33390G 36549S 56930G 948502 35889A 35026G WNZ015 OVEN CAVITY PARTS ...

Страница 30: ...6 5 466001 43500A WSZ085 466003 466001 44510A LATCH BOARD PARTS ...

Страница 31: ...6 6 56411A 568771 56930V 50FZZA 56201A 55900A WTT037 56549F WSZ002 WSZ002 WSZ062 WTT021 33808A 54974S WSZ002 WTT028 56851D 50CZZH 948501 54810C 56912B 55262A 56324A 34930W WSZ002 INTERIOR PARTS ...

Страница 32: ...6 7 56170D 63302A 65006B WTT021 WSZ002 63303A BASE PLATE PARTS ...

Страница 33: ...P NO 3828W5S3283 June 2003 Printed in Korea ...

Отзывы: