background image

K. TIMER MOTOR REMOVAL

1) Remove the control panel assembly from the

cavity. 

2) Remove screws which hold the timer motor to the

control panel.

3) Remove the timer motor from the control panel.
4) Remove the power control knob and the timer

knob.

L. INTERLOCK SYSTEM

1) INTERLOCK MECHANISM

The door lock mechanism is a device which has
been specially designed to eliminate completely
microwave activity when the door is opened during
cooking and thus to prevent the danger resulting
from the microwave leakage.

2) MOUNTING OF THE PRIMARY/MONITOR/

SECONDARY SWITCHES TO THE LATCH
BOARD

3) INSTALLATION AND ADJUSTMENT OF THE

LATCH BOARD TO THE OVEN ASSEMBLY

• Mount the latch board to the oven assembly.
• Adjust the latch board in the arrow direction so that

oven door will not have any play in it when the door
is closed.

• Tighten the mounting screw.
• Check for play in the door by pushing the door

release button. Door movement should be less
than 0.5 mm. (1/64 inch)

Don't push the door release button while making

adjustment. Make sure that the latch moves
smoothly after adjustment are completed and that
the screws are tight. Make sure the primary, monitor,
and secondary switches operate properly by
following the continuity test procedure.

5-6

Control Panel

Timer Motor

Power Control 

Knob

Timer Knob

AC Relay

PRIMARY
SWITCH

ADJUSTMENT
DIRECTION

MONITOR
SWITCH

SECONDARY
SWITCH

CAUTION: CHECK THE CORRECT POSITION

MAGNETRON

H.V. TRANSFORMER

PRIMARY

CIRCUIT PROTECTOR

H.V. CAPACITOR

H.V.
DIODE

FIG. 1

Содержание MB-392A

Страница 1: ...ich is graduated to 600 cc and place the beaker on the center of the turntable Set the energy leakage monitor to 2 450 MHz and use it following the manufacturer s recommended test procedure to assure correct result When measuring the leakage always use the 2 inch 5cm spacer supplied with the probe Operate the oven at its maximum output Measure the microwave radiation using and electromagnetic radi...

Страница 2: ...ter than 1 inch sec 2 5 cm sec along the shaded area otherwise a false reading may result The test probe must be held with the grip portion of the handle A false reading may result if the operator s hand is between the handle and the probe When testing near a corner of the door keep the probe perpendicular to the surface making sure the probe horizontally along the oven surface this may possibly c...

Страница 3: ...perature is 5 K The microwave power output P in watts is calculated from the following formula is measured while the microwave generator is operating at full power Magnetron filament heat up time is not included about 3 sec The water is stirred to equalize temperature throughout the vessel prior to measuring the final water temperature Stirring devices and measuring instruments are selected in ord...

Страница 4: ...1 Discharge the high voltage capacitor 2 Disconnect the leadwire from magnetron high voltage transformer and capacitor 3 Remove the screw holding the high voltage transformer to the baseplate F FAN MOTOR ASSEMBLY REMOVAL 1 Discharge the high voltage capacitor 2 Disconnect the leadwire from fan motor noise filter and high voltage capacitor 3 Remove the two screws holding the the suction guide ASS Y...

Страница 5: ... 5 mW cm2 With a 275 ml water load Make sure that gasket is rigidly attached to the magnetron To prevent microwave leakage tighten the mounting screws properly making sure there is no gap between the waveguide and the magnetron J REMOVING THE TURNTABLE MOTOR 1 Remove the turntable 2 Remove the Rotating Ring 3 Lay the unit down on its back 4 Remove the turntable motor cover The turntable base cover...

Страница 6: ...SSEMBLY Mount the latch board to the oven assembly Adjust the latch board in the arrow direction so that oven door will not have any play in it when the door is closed Tighten the mounting screw Check for play in the door by pushing the door release button Door movement should be less than 0 5 mm 1 64 inch Don t push the door release button while making adjustment Make sure that the latch moves sm...

Страница 7: ... closed meter should indicate an closed circuit When the secondary switch operation is abnormal make the necessary adjustment or replace the switch only with the same type of switch C MONITOR SWITCH TEST Disconnect the wire lead from the monitor switch Connect the ohmmeter leads to the common COM and normally closed NC terminals of the switch The meter should indicate closed circuit in the door op...

Страница 8: ...S TEST PROCEDURE RESULTS HIGH VOLTAGE TRANSFORMER Wire leads removed MAGNETRON Wire leads removed 1 Measure the resistance Ohm meter scale Rx1 and Rx100 Primary winding Secondary winding Filament winding 2 Measure the resistance Ohm meter scale Rx1000 Primary winding to ground Filament winding to ground 1 Measure the resistance Ohm meter scale Rx1 Filament terminal 2 Measure the resistance Ohm met...

Страница 9: ...r scale Rx1000 Terminal to case Measure the continuity Forward Ohm meter scale Rx10000 Measure the continuity Reverse Ohm meter scale Rx10000 Normal Momentarily indicates several ohms and then gradually returns to infinite Normal Normal Continuity Abnormal Normal Abnormal Continuity NOTE When testing the magnetron be sure to install the magnetron gasket in the correct position and be sure that the...

Страница 10: ...e replacing the fuse If the fuse is blown by improper switch operation replace the defective switch and the fuse at the same time Replace just the fuse if the switches operate normally NOTE Make sure heater is fully cooled when tested Measure the resistance Multi meter scale Rx1 Normal Grill heater Approx 50 Ω at 20 30 C Normal more than 200 MΩ Normal Abnormal Measure the resistance with 500V 100M...

Страница 11: ...scale R x 1000 Normal Abnormal or several Ω Normal Approx 100 200 Ω Abnormal or several Ω NOTE A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS SERVICED FOR ANY REASON MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION WHEN REMOVING THE WIRE LEADS FROM THE PARTS BE SURE TO GRASP THE CONNECTOR NOT THE WIRES A B C Turn On Turn Off A B Grill Switch Microwave Switch Approx 22 KΩ No...

Страница 12: ...el to discharge any static charge built up in your body CONDITION Microwave oven does not work Inserting many plug into one plug outlet and using them at the same time causes overloading Microwave oven plug is not inserted tightly Output power is too low Low AC input voltage Food temperature is too low Using metallic ware and allowing it to touch the oven wall Sparks occurring Inconsistent intensi...

Страница 13: ...ned Disconnect one side of the wire lead connected from transformer to the high voltage capacitor and operate the unit Replace fuse 1 Oven does not operate No continuity No continuity Adjust or replace Malfunction of the primary switch Malfunction of the secondary switch Adjust or replace Check the continuity of the primary switch with door closed Check the continuity of the secondary switch with ...

Страница 14: ...ician Check the power source voltage oscillating No continuity No continuity replace Malfunction of the timer switch Faulty thermostat replace Check the continuity of the timer switch contacts Check the continuity of the thermostat CONDITION CHECK RESULT CAUSE REMEDY TROUBLE 4 Grill CONDITION CHECK RESULT CAUSE REMEDY 1 Heater is not operating Abnormal Normal Normal Heater Thermostat Grill Abnorma...

Страница 15: ...oking state Check the monitor resistor Abnormal Defective AC relay Replace Normal Check the AC relay Abnormal Open the secondary winding of the high voltage transformer of faulty insulation of filament winding Replace Check H V transformer Abnormal Shorted H V diode Replace Check H V diode Abnormal Faulty capacitor Replace Check H V capacitor Abnormal Faulty magnetron Replace Magnetron TROUBLE 5 O...

Отзывы: