5-14
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace primary
and monitor
switches.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace primary
and monitor
switches.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
(TROUBLE 2) Oven does not operate at all ; Display window does not display any figures and
no input is accepted.
NOTE : All these switches must be replaced at the same time. Refer to page 5-6, 5-7
2. Fuse does not
blow.
No continuity.
No continuity.
Replace power
supply cord.
Defective mag-
netron thermostat.
Defective power
supply cord.
Replace mag-
netron thermostat.
Check continuity
of magnetron
thermostat.
Check continuity
of power supply
cord.
Continuity.
Содержание MB-387W
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 29: ...6 2 13581A 14970A 14026A 13552A 13213A 14890A 13720D 13536A DOOR PARTS EV ...
Страница 30: ...6 3 268711 24781S 23790D 23572A 250202 249402 249401 250201 250203 WTP004 CONTROL PANEL PARTS EV ...
Страница 32: ...6 5 LATCH BOARD PARTS 43500A 466001 466003 466001 44510A WSZ085 EV ...
Страница 34: ...6 7 56170D 63302A 65006B WTT021 WSZ002 63303A BASE PLATE PARTS EV ...
Страница 35: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 36: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 37: ......