5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENT TEST PROCEDURE
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 1.4 ohm
Approx.: 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
PRIMARY
TERMINAL
SECONDARY
TERMINAL
FILAMENT
WINDING
TERMINAL
Содержание MB-3832E
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 28: ...6 2 13581A 14970A 14026A 13552A 13536A 13213A 14890A 13720D DOOR PARTS ...
Страница 29: ...6 3 24781S WTP004 268711 23572A 250201 249401 249402 23790D CONTROL PANEL PARTS ...
Страница 31: ...6 5 466001 43500A WSZ085 466003 466001 44510A LATCH BOARD PARTS ...
Страница 33: ...6 7 56170D 948503 63302A WSZ002 WTT021 65006B 63303A BASE PLATE PARTS ...
Страница 34: ...SCHEMATIC DIAGRAM OF P C B 8 1 ...
Страница 35: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 36: ...P NO 3828W5S2645 May 2003 Printed in Korea ...