5-13
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace primary
and monitor
switches.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace primary
and monitor
switches.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
(TROUBLE 1) Oven lamp does not turn on when the timer knob is turned with door closed.
NOTE : All these switches must be replaced at the same time. Refer to page 5-6, 5-7
2. Fuse does not
blow.
No continuity.
No continuity.
Replace power
supply cord.
Defective oven
thermostat.
Defective power
supply cord.
Replace oven
thermostat.
Check continuity
of oven
thermostat.
Check continuity
of power supply
cord.
Continuity.
Содержание MB-3832E
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 28: ...6 2 13581A 14970A 14026A 13552A 13536A 13213A 14890A 13720D DOOR PARTS ...
Страница 29: ...6 3 24781S WTP004 268711 23572A 250201 249401 249402 23790D CONTROL PANEL PARTS ...
Страница 31: ...6 5 466001 43500A WSZ085 466003 466001 44510A LATCH BOARD PARTS ...
Страница 33: ...6 7 56170D 948503 63302A WSZ002 WTT021 65006B 63303A BASE PLATE PARTS ...
Страница 34: ...SCHEMATIC DIAGRAM OF P C B 8 1 ...
Страница 35: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 36: ...P NO 3828W5S2645 May 2003 Printed in Korea ...