5-18
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Heater is not
operating
2. Lower tempera-
ture in the oven.
Normal
No continuity
Open or loosen.
Replace or
connect tighty
Malfunction the
heater.
Replace
Heater
Abnormal
Wire connection
Output is full power
when you set lower
power level.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Abnormal
Malfunction the
heater
Replace
Normal
Heater
Abnormal
Defective PCB
assembly.
Replace PCB
assembly
Disconnect the
wire leads from
relay 3 and
check continuity
relay 3.(Operate
the unit)
(TROUBLE 6) Grill