5-16
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Setting time
does not count
down when
touching START
pad.
2. Fan motor or
oven lamp do
not turn on.
No continuity.
Continuity.
Continuity
Defective PCB
assembly.
Loose connection.
Replace PCB
assembly.
Connect them
tightly.
No continuity
Abnormal
Check fan motor.
Defective fan motor.
Replace fan motor.
Abnormal
Normal
Check oven lamp.
Defective oven lamp.
Replace oven lamp.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
CN1 connector
and PCB
assembly.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired
program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operating but little heat is produced in oven load.
NOTE : Simple test of power output-conducted by heating one liter water for one min. if available.
Minimum 8.5°C temperature rise is normal condition.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 90% of
rating voltage.
Normal
Abnormal
Defective PCB
assembly.
Replace PCB
assembly.
Normal
Abnormal
Measure the
output power.
Defective
magnetron.
Replace
magnetron.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
Disconnect the
wire leads from
relay 2 and
check on and off
time with
multitester.
Содержание MB-309XE
Страница 30: ...6 2 13213A 13552A 15006A 13536A 13581A 14026A 14970A 13720D 13352A DOOR PARTS ...
Страница 31: ...6 3 26638A 23572A 268771 24781M WTP018 WTP028 24510L 250201 24970A CONTROL PANEL PARTS ...
Страница 34: ...6 6 WSZ002 56411A 56324A WSZ002 54810A 56930G 54826A WTP028 WTP006 WTP004 968101 INTERIOR PARTS ...
Страница 36: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 37: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 38: ...July 1997 Printed in Korea P NO 3828W5S0450 December 1998 P NO 3828W5S0960 Printed in Korea ...