background image

Safety Precautions

10 Multi Type Air Conditioner

ON

Cooling

Healthy

Dehumidification

Auto

Heating

(Heat pump model only)

To lower the temperature

To raise the temperature

(Cooling Only

model)

(Heat Pump

model)

Open the door on the Remote Controller. To select Cooling
Operation
, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is shifted
in the direction of the arrow.

Set the temperature lower than the room temperature.
The temperature can be set within a range of 18°C~30°C in
1°C.

You can select the fan speed in four steps-
low, medium, high, or CHAOS. Each time the
button is pressed, the fan speed mode is
shifted.

Cooling Operation

Natural wind by the CHAOS logic

For more fresh feeling, press the Indoor Fan Speed Selector and set CHAOS mode. In this mode, the wind
blows like natural breeze by automatically changing fan speed according to the CHAOS logic.

Press the Start/Stop button.
The unit will respond with beep sound.

1

2

3

4

Содержание MA09AH

Страница 1: ...alling and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 2 EN 61000 3 Norm ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH ...

Страница 2: ... you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not pla...

Страница 3: ...ic shock Do not handle the flamable gas or explosive materials near the product Do not install where flamable gas could leak Otherwise it may cause fire or failure of product Otherwise it may cause esplosion or fire Do not install the product on an defected installation stand Be cautious when unpack and install the product Otherwise It may cause injury or accident Sharp edges could cause injury Fo...

Страница 4: ...ver the electric part Otherwise it may cause fire or electric shock Do not turn the breaker on off or connect disconnect the power supply plug during operation Otherwise it may cause fire or electric shock Do not open the suction inlet of the product during operation Otherwise it may cause electric shock or failure Do not touch the metal parts of the product when removing the air filter Otherwise ...

Страница 5: ...not use wax tinner or a strong detergent etc Do not drink water drained from the product Otherwise it may change the apperance of the product Otherwise it may harm to your health Do not insert your hand or bars etc into the air inlet outlet Do not use the product at the closed space for a long time Otherwise it may cause personal injury Otherwise it may cause suffocation due to poor oxygen Do not ...

Страница 6: ...eserving precision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the po...

Страница 7: ... according to the arrow direction Insert new batteries making sure that the and of battery are installed correctly Reattach the cover by sliding it back into position Use 2 AAA 1 5volt batteries Do not use rechargeable batteries NOTICE 3 2 1 The refering to the following picture fix the remote controller holder onto the wall using screws To operate the room air conditioner aim the Remote Controlle...

Страница 8: ...ature For cooling dehumidification heating modes it display Destired temperature indicator Cooling 18 30 C AI Auto Operation Dehumidification 18 30 C Po Jet Cool Heating 16 30 C Lo Test Mode Desire temperature Icon Indoor temperature Icon Receives the signals from the remote controller Signal receiving sound two short beeps or one long beep Operation Indication Lamps Lights up during the system op...

Страница 9: ...eed cooling heating operates super high fan speed CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up down airflow direction ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation TIME SETTING BUTTONS Used to adjust the time TIMER SET CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation SLEEP MODE ...

Страница 10: ... direction of the arrow Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C in 1 C You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Cooling Operation Natural wind by the CHAOS logic For more fresh feeling press the Indoor Fan Speed Selector and set CHAOS mode In t...

Страница 11: ...ols based on the actual room temperature If you want to change the set temperature press the Room Temperature Setting buttons The set temperature will be changed considering room temperature DURING AUTO OPERATION You cannot switch the indoor fan speed It has already been set by the Fuzzy rule If the system is not operating as desired manually switch to another mode The system will not automaticall...

Страница 12: ... dehumidification mode on the operation selection button the A C starts to run the dehumidification function automatically setting the room temp and air volume to the best condition for dehumidification based on the sensed room temp In this case the setting temp is not displayed in the Remote Controller and you are not able to control the room temp either During the healthy dehumidification functi...

Страница 13: ...shifted in the direction of the arrow NATURAL WIND BY THE CHAOS LOGIC For more fresh feeling than other fan speed press the Indoor Fan Speed Selector and set to CHAOS mode In this mode the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic 1 2 Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in ...

Страница 14: ... unit will operate in high fan speed in cooling heating mode 1 2 3 Jet Cool function in heating mode is available on Artcool type only During the JET COOL function at any moment the A C starts to blow the cool heat air at extremely high speed for 30 60 minutes setting the room temp automatically to 18 C 30 C It is especially used to cool heat the room temperature in the shortest time In order to r...

Страница 15: ...en the button is pressed and stop when the button is pressed again Set the fan speed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Air purifying operation PLASMA is available in Heating or any other operations 1 2 3 NANO PLASMA Purification Operation Optional If you press the PLASMA button NANO PLASMA air purifying...

Страница 16: ... sound Open the door of the Remote Controller and press the 2nd F button to operate functions printed in blue at bottom of buttons Check the indication of 2nd function on Remote Controller display These buttons operate the timer setting as follows 2nd function goes off in a short time automatically or when the button is pressed again For more details refer to functions next page 1 2 3 ...

Страница 17: ...nutes and by 2 C in 1 hour for comfortable sleeping NOTICE 1 Time can be set only when you have pressed the Reset button If you have just replaced the batteries the Reset button should be pressed to reset the time Press the Start Stop button 2 Press 2nd F button and check if 2nd F icon is on 3 Press the Time Setting buttons until the desired time is set 4 Press the Timer SET button Check the indic...

Страница 18: ...te Controller to adjust the up down airflow direction Manually moving the vertical airflow direction louver by hand could damage the air conditioner When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system To adjust left right Horizontal Airflow direction Caution Ensure that the unit is turned off before adjusting the horizontal airflow direction ...

Страница 19: ... minute and circulates the room air without cooling and heating for 14 minutes And then unit stops operating NOTE During Auto Clean function moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed During Auto Clean function only Start Stop button Plasma button and Auto Clean button are available Auto Clean Artcool Artcool Deluxe Type Only Display...

Страница 20: ...ower failure the unit operates automatically to the previous operating conditions So there is no need of activating this function by pressing any key or button In the initial mode the fan operates at a low speed and the compressor starts about 3 minutes later As the compressor starts the fan speed also resumes its previous setting mode Helpful information Fan speed and cooling capacity The cooling...

Страница 21: ... to remove the filter 2 Clean the filter with a vacuum cleaner or warm soapy water If dirt is conspicuous wash with a solution of detergent in lukewarm water If hot water 40 C or more is used it may be deformed 3 After washing with water dry well in the shade 4 Re install the air filter NOTICE Vertical louver Horizontal louver Air filters behind front panel Air outlet vent Air inlet vent Gasoline ...

Страница 22: ...it and take the filter out slowly Notice Clean the filter after being stopped the product 2 Clean the filter with a vacuum or warm soapy water If dirt is conspicuous wash with a solution of detergent in lukewarm water If hot water 40 C or more is used it may be deformed 3 After washing with water dry well in the shade 4 Re install the air filter NOTICE Replacement of Purifying Filter Optional Reco...

Страница 23: ...e neutral detergent for 1 2 hours and then raise them 4 Insert the Plasma Filter after perfectly drying in shade Now insert Air Filter and close the Front panel Completely by matching the hook Air Filter Air Filter Front Panel Hook Hook Hanger Air Filter Plasma Purifier Filter Front Panel Front panel Panel hook Artcool Deluxe Type Indoor Unit 1 Open the upside of Front Panel 2 Lift up the Front pa...

Страница 24: ...s Water hotter than 40 C Could cause deformation and or discoloration Volatile substances Could damage the surfaces of the air conditioner Don t touch this nano PLASMA Filter within 10 seconds after opening the inlet grille it may cause an electric shock Cleaning of Purifying Filter Recomended use period About 3 months 1 Open the upside of Front panel 2 Put up the front panel The hook of panel com...

Страница 25: ... Refer to page 22 24 for cleaning filters Check that the air inlet and outlet of the indoor outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows if possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the ro...

Страница 26: ...oth items in the room Check the drain hose is connected tight or if indoor unit is installed even This is the protector of the mechanism Wait about 3 minutes and operation will begin About 3 minutes delay is applied to protect compressor from frequenty on off Is the air filter dirty See air filter cleaning instructions Has the temperature been set correctly Are the indoor unit s air inlet or outle...

Отзывы: