background image

Installation Manual 

5

ENGLISH

Safety Precautions   

For installation, always
contact the dealer or an
Authorized Service Center.

• There is risk of fire, electric

shock, explosion, or injury.

Do not install the product on a
defective installation stand.

• It may cause injury, accident, or

damage to the product.

Do not let the product run for a
long time when the humidity is
very high and a door or a
window is left open.

• Moisture may condense and wet

or damage furniture.

For re-installation of the
installed product, always
contact the dealer or an
Authorized Service Center.

• There is risk of fire, electric shock,

explosion or injury.

Do not open the
maintenance cover of the
main body during operation.

• Otherwise, it may cause electrical

shock.

Use the outdoor air suction
hole with the net installed to
ensure that birds could not
come in.

• Remove estrange things like the

bird’s nest. Otherwise, it may
cause scarcity of indoor oxygen.

Install the air intake where
polluted air can not be
directly sucked in.

• It may cause various accidents,

including suffocation, due to the
suction of harmful gasses(CO, etc.) 

Do not install this product in
a refrigerated warehouse,
heated swimming pool or
other location where the
temperature and humidity
are significantly different.

• There is risk of electrical shock,

malfunctioning.

Install this product in an
environment where the
temperature ranges from –10°C to
+45°C and the relative humidity is
less than 80%. It condensation is
expected to form, heat up the fresh
outside air using a duct heater etc.

Install this product in and
environments where the outside
air intake meets the following
conditions: temperature range
is between –15°C and +40°C and
the relative humidity is 80% or
less.

Use the designated electrical
wires for the terminal board
connections, and connect the
wires securely so that they will
not become disconnected.
(Failure to ensure proper
connections may cause fire.)

When passing metal ducts
through wooden buildings clad
with metal laths, wire laths or
metal, these ducts must be
installed in such a way that they
will not make electrical contact
with the metal laths, wire laths
or metal sheets. (Power leakage
can cause ignition)

Avoid fire equipment

• There is risk of fire.

When the product is soaked
(flooded or submerged), contact
an Authorized Service Center. 

• There is risk of fire or eletric shock.

Don't touch a dedicated circuit
or breaker with wet hands.

• There is risk of electric shock.

Operation

When the product is not be
used for a long time,
disconnect the power supply
plug or turn off the breaker.

• There is risk of product damage or

failure, or unintended operation.

Do not store or use flammable
gas or combustibles near the
product.

• There is risk of fire or failure of

product.

When flammable gas leaks,
turn off the gas and open a
window for ventilation
before turn the product on.

• Do not use the telephone or

turn switches on or off. 
There is risk of explosion or fire

Содержание LZ-H080GBA2

Страница 1: ...t Installation work must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly TYPE VENTILATOR ENGLISH FRANCAIS ESPAÑOL LG Electronics U S A Inc Englewood Cliffs NJ All rights reserved LG Life s Good is a registered trademark of LG Corp ...

Страница 2: ...ions Please read these instructions completely before installing the product Failure to carefully read and follow all instructions in this manual can result in equipment malfunction property damage personal injury and or death ...

Страница 3: ... Map 9 Installation of Main Body 11 Connection of Duct 11 Method to Connect Power Cord 13 Conduit connection 14 Group control 15 How to connect Central Controller Accessory 17 In case of finding a problem at a trial operation 18 Screws Nuts Ceiling Fixing Bolt M10 12 Washer Aluminium Tape Screws Screw Driver Spanner Cutter Cutter Screw Driver Installation Requirements Required Parts Required Tools...

Страница 4: ... the product There is risk of fire or electric shock Always ground the product There is risk of fire or electric shock Install the panel and the cover of control box securely Failure to use correctly rated breakers or fuse may cause fire or electric shock Always install a dedicated circuit and breaker Improper wiring or installation may cause fire or electric shock Use the correctly rated breaker ...

Страница 5: ...rature ranges from 10 C to 45 C and the relative humidity is less than 80 It condensation is expected to form heat up the fresh outside air using a duct heater etc Install this product in and environments where the outside air intake meets the following conditions temperature range is between 15 C and 40 C and the relative humidity is 80 or less Use the designated electrical wires for the terminal...

Страница 6: ...ing occurs inside of the main body in winter and it causes electrical shock or falling of condensed water Installation Keep level even when installing the product To avoid vibration or water leakage Use two or more people to lift and transport the product Avoid personal injury Do not install the product where it will be exposed to sea wind salt spray directly It may cause corrosion on the product ...

Страница 7: ...eturnAir SA SupplyAir OA OutdoorAir EA ExhaustAir Model LZ H080GBA2 ARVU053ZEA2 LZ H100GBA2 ARVU063ZEA2 Model 1062 1140 365 987 1176 180 250 242 253 98 513 481 67 41 8 44 9 14 4 38 9 46 3 7 1 9 8 9 5 10 3 9 20 2 18 9 147 7 A B C D E F G H J K L kg lb LZ H080GBA2 ARVU053ZEA2 LZ H100GBA2 ARVU063ZEA2 Figure Duct Pitch Weight Pitch of Suspension Fixture Duct Connection Flange Nominal Diameter Unit mm ...

Страница 8: ...7 1140 44 9 738 29 1 987 38 9 1176 46 3 339 13 3 242 9 5 253 10 98 3 9 340 13 4 350 13 8 146 321 9 A B C D E F G H J K L kg lb LZ H150GBA2 ARVU093ZFA2 LZ H200GBA2 ARVU123ZFA2 Figure Weight Pitch of Suspension Fixture Duct Connection Flange Unit mm inch Service clearances for maintenance must be added to dimension diagram above refer to product engineering manual for required service clearances ...

Страница 9: ...nting Penetration of Rain Water 1m 39 4in Ceiling Fixing Bolt Supplied by installer RA Grille SA Grille Ventilator Inspection Hatch SA EA OA RA 1m or more 1m or more Installation Map LZ H080GBA2 ARVU053ZEA2 LZ H100GBA2 ARVU063ZEA2 A PLANE FIGURE A FRONT VIEW Maintenance Cover Control Box SA Grille Ventilator Main Body Maintenance Space More than 600mm EA OA Inspection Hatch 600x600mm2 600mm 23 6in...

Страница 10: ...ting Penetration of Rain Water New Type Hood Preventing Penetration of Rain Water 1m 39 4in Ceiling Fixing Bolt Supplied by installer RA Grille SA Grille Inspection Hatch SA SA EA OA RA RA 1m or more 1m or more A PLANE FIGURE A FRONT VIEW Maintenance Cover Control Box SA Grille THREE DIMENSION VIEW INSTALLATION OF MAINTENANCE COVER Ventilator Main Body Maintenance Space More than 600mm EA OA Inspe...

Страница 11: ... in the right figure For the ceiling fixing bolt perform work less than 50mm 1 97in under the ceiling fixing bracket Connection of Duct 1 After securely connect the duct with the duct connection flange wrap it with a commercial aluminium tape so that air cannot be leaked 2 Adjust the duct from the ceiling so that no force is applied to the main body of the ventilation system 3 Always use two ducts...

Страница 12: ...forming the duct connection work It is recommended to perform adiabatic treatment even to the duct pipe at the indoor side where ambient temperature is expected higher than room temperature when the main body of the ventilation system for cooling in summer Take care so that work may not be performed as in the left figure Otherwise it may cause reduction of air volume or abnormal noise CAUTION In 1...

Страница 13: ...the power cord into the bushing fully insert it into the terminal block for connection Fix the power cords with the clamp Make sure that the power cords may not be removed by pulling them 3 Wiring specifications Wiring specifications Sheathed wire should be complied with IEC60245 standard NRTL recognized UL CSA ETL Length MAX 100m 109 4yd External contact specifications Normally closed contact Cur...

Страница 14: ...signated power wire and connect firmly then secure to prevent outside pressure being exerted on the terminal block Use an appropriate screwdriver for tightening the terinal screws A screwdriver with a small head will strip the head and make proper tighterning impossible Over tightening the terminal screws may break them When none are available follow the instructions below Do not connect wiring of...

Страница 15: ...hange the master slave setting from the indoor unit Indoor units the master slave configuration of the product after completion of indoor unit power OFF and then ON the power after 1 minutes elapsed sign up For ceiling type cassette and duct product group change the switch setting of the indoor PCB For wall mount type and stand type product change the master slave setting with the wireless remote ...

Страница 16: ...e used as part of the combined operation system used together with indoor units Multi V system air conditioners or as an independent system for processing outside air Combined operation system with Multi V system connected with ventilation units and standard indoor units in a single refrigerant circuit Independent system connected only with a ventilation unit in a single refrigerant circuit ...

Страница 17: ...ct between PI485 Gate Way CN OUT and Main PCB CN CC 2 You do not need to set the Option Switch of Main PCB 3 Please refer to the manual of Accessory for the detail installation method How to connect Central Controller Accessory CN CC CN OUT Main PCB PI485 Gate Way Central controller ...

Страница 18: ...king the power rated power 1 phase 208V 230V the diameter ø0 6 ø2 0 capacity of breaker Isn t the fuse connected Are the PCB and Remote Controller rightly connected Is the outdoor temperature the limit temperature Less than 10 C 14 F more than 45 C 113 F In case of the limit temperature Switch on Option No 5 Repower the product and check whether it works or not Switch off Option No 5 and repower t...

Страница 19: ......

Отзывы: