—2—
POWER SUPPLY
COOLING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(BTU/W.h)
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN / COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
COMPRESSOR
PROTECTOR
FAN MOTOR
ELECTRIC HEATER
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W x H x D)
(mm)
1ø, 208~230V, 60Hz
10,000
12,000
1,020
970
1,000
4.9
4.6
9.8
12.0
26.7(DB)* 19.4(WB)**
35(DB)* 23.9(WB)**
510g (18 OZ)
390g (13.8 OZ)
2 ROW 13 STACKS LOUVERED-FIN TYPE
2 ROW 17 STACKS, LOUVERED-FIN TYPE
BLOWER
TURBO
PROPELLER TYPE FAN WITH SLINGER-RING
2/3
3/3
2/3
6 POLES
ROTARY SWITCH
WIRELESS REMOCON
ROTARY SWITCH
THERMOSTAT
THERMISTOR
THERMOSTAT
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
FUSE LINK, BIMETAL THERMOSTAT
(3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
90/41
95/43
97/44
23
5
/
8
x 14
31
/
32
x 22
5
/
16
600 x 380 x 567
LWC1031ACG,
LWC1032ACG
LWC1031NCN/P,
LWC1031SCG
LWC1032PCG,
LWC1032TAS
LWC123CNAA1
MODEL
ITEMS
OPERATING
CONDITION
* DB:Dry Bulb
** WB:Wet Bulb
1. SPECIFICATIONS
• MODELS : LWC1031ACG/LWC1032ACG/LWC1031NCN/P, LWC1031SCG, LWC1032PCG/TAS, LWC123CNAA1
2 ROW 16 STACKS
LOUVERED-FIN TYPE
2 ROW 18 STACKS
LOUVERED-FIN TYPE