Window Requirements
●
This unit is designed for installation in standard
double hung windows with actual opening
widths from 22" to 36".
The top and bottom window sashes must open
13" from the bottom of the upper sash to the
inside sill.
22" to 36"
13" min
Preparation of Unit
1
Indoors
Inner Sill
Outer Sill
Storm
Window Frame
Wood Strip Mounted
on Top of Inner Sill
¾"
Clearance
Wood Strip for
L bracket
L Bracket
Outdoors
NOTE
●
This prodcut is a WINDOW AIR CONDITIONER.
As such, a standard single-hung or double-hung
window is required for proper installation.
No-window installations, including using sleeves,
holes in walls, and other installations are not
recommended.
1
If a storm window presents interference,
fasten a 2” wide wood strip to the inner
window sill across the full width of the sill.
The wood strip should be thick enough to
raise the height of the window sill so that
the unit can be installed without interference
by the storm window frame.
2
(See drawing.) The top of the wood strip on
the inside sill should be approximately ¾”
higher than the storm window frame or wood
strip on the outside sill to help condensation
to drain properly to the outside.
3
If necessary, install a second wood strip
(same thickness as first strip) in the center
of sill flush against the back off the inner sill.
This will raise the L bracket as shown in
the drawing.
Clearance
Proper clearance enhances the cooling efficiency
of the product.
How to Install the Unit
1
To prevent vibration and noise, make sure
the unit is installed securely and firmly.
4
Install the unit slightly tilted so the back is
slightly lower than the front (about 1/4").
This will force condensed water to flow to
the outside.
5
Install the unit with the bottom between
30" ~60" above the floor level.
2
Install the unit where the sunlight dose not
shine directly on the unit.
3
The outside of the cabinet must extend out-
ward for at least 12" and there should be no
obstacles, such as a fence or wall, within 20"
from the back of the cabinet because it will
prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
Fence
Awning
Heat
radiation
Cooled air
CAUTION
●
All side louvers of the cabinet must remain
exposed to the outside of the structure.
4
Upper Panel Guide
Right Curtain Panel
Left Curtain Panel
Lower Panel
Guide
Insert the top and bottom rails of the curtain
panels into the upper and lower panel
guides.