–34–
1) Connecting cables to the Indoor Unit
1) Remove the Air guide - L by loosening 2 screws
after removing the Inlet grille from the Indoor
unit.
2) Connect the wires to the terminals on the con-
trol board individually according to the outdoor
unit connection.
• Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively
R
AIR GUIDE-L
INDOOR UNIT
Control
Panel
1
2
Clamp
NORMAL CROSS-
SECTIONAL AREA
• 2.5mm
2
(24K)
• 2.0mm
2
(18K:for the Middle East)
• 1.5mm
2
(18K:for the other area)
NORMAL CROSS-
SECTIONAL AREA
• 2.5mm
2
(24K)
• 2.0mm
2
(18K:for he Middle East)
• 1.5mm
2
(18K:for he other area)
NORMAL
CROSS-
SECTIONAL
AREA
0.75mm
2
The power cord
connected to the
indoor unit should be complied with
the following specifications
(Type H05VV-F(Indoor)
approved by HAR or SAA).
The power connecting cable
connected between the indoor and
outdoor unit should be complied
with the following specifications
(Type H07RN-F approved by HAR or SAA).
The connecting cable
connected
between the indoor and outdoor unit
should be complied with the
following specifications
(Type H07RN-F approved by HAR or SAA).
CAUTION
Ø8.0mm
Ø10.0mm
Ø8.0mm
Ø10.0mm
Ø6mm
6. Connecting Cables between Indoor Unit and Outdoor Unit
2) Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly.
For the heat pump model, put the 0.75mm
2
cable(thinner cable) on the clamp and tighten it with a plastic clamp to the oth-
er boss of the control panel.
4) In Australia, the length of power supply cord measured from the entry of the power supply cord to the middle of live pin on
the power plug should be over 1.8m.