background image

23

INSTALLATION

ENGLISH

4-Wire Connection : Power Cord

WArnInG

 

Only a 4-conductor power-supply cord kit 

rated 120/208 or 120/240 volts, 50 amperes 

and marked for use with ranges with closed-

loop connectors or opened spade lugs with 

upturned ends shall be used. 

The white middle (neutral) wire of the power 

cord or 4-wire conduit has to be connected 

to the middle post of the main terminal 

block. The other two wires of the power 

cord or conduit have to be connected to 

the outside posts of the main terminal 

connection block. The 4th ground wire 

(green) must be connected to the frame of 

the range with the ground screw. 

Failure 

to do so can result in electrical shock, severe 

personal injury or death.

Install the power cord as follows:
Do not install the power cord without a strain 

relief.

1

Remove the lower 3 screws from the terminal 

block and retain them.

2

Remove the ground screw and bend the end of 

the ground strap up so the slot is over the hole 

of the center screw removed in step 1.

3

Insert the ground screw into the power cord 

ground wire (green) terminal ring and secure it to 

the range frame.

4

Insert the 3 screws through each power cord 

terminal ring and into the lower terminals of the 

terminal block. Make sure that the white center 

(neutral) wire is connected to the center lower 

position of the terminal block.

5

Tighten the 3 screws securely into the terminal 

block. The center screw now attaches the bent 

up ground strap to the block.

4-wire connection

Ground 

strap

Terminal 

block

Conduit 

connection plate

Ground 

screw

Black White Red

Bend strap up 

and attach

If screws are not tightened securely, it can result in 

electrical spark and severe personal injury or death.

3-Wire Connection: Conduit

Install the conduit as follows:

Remove the conduit connection plate from the rear of 

the oven and rotate it. The conduit hole (1

1

/

8

") must 

be used.
First, prepare the conduit wires as shown below.

3-Wire

Conduit 

connection 

plate

Ground 

wire

or

4-Wire

Second, install the conduit strain relief.
For conduit installations, purchase a strain relief and 

insert it in the 1

1

/

8

 in. (2.8 cm) conduit hole. Then 

install the conduit through the body of the strain relief 

and fasten the strain relief with its ring. Reinstall the 

bracket. 

For conduit connections: 

If the wire in the conduit is copper it must be 8 or 10 

AWG wiring. 

If the wire in the conduit is aluminum it must be 6 or 8 

AWG wiring.

1

Loosen the lower 3 screws from the terminal 

block.

2

Insert the bare wire (white/neutral) end through 

the center terminal block opening. Do not 

remove the ground strap connections.

3

Insert the two side bare wire ends into the lower 

left and the lower right terminal block openings. 

Tighten the 3 screws securely into the terminal 

block. (approximately 35 - 50 IN-LB)

3-wire connection

Terminal 

block

Black White Red

Wire 

ends

Conduit 

connection plate

If screws are not tightened securely, it can result in 

electrical spark and severe personal injury or death.

Содержание LUTD4919SN

Страница 1: ...te Black White Red Terminal block 240 V or 208 V Pressure regulator Product Specifications The appearance and specifications listed in this manual may vary due to constant product improvements Oven Range Models LUTD4919SN Description Dual Fuel Double Oven Range Electrical requirements 6 9 kW 120 240 VAC or 5 2kW 120 208 VAC Exterior Dimensions 29 7 8 W x 37 59 64 H x 28 15 16 D D with door closed ...

Страница 2: ...esult in fire electrical shock property damage personal injury or death Wear gloves during the installation procedure Failure to do so can result in bodily injury Make sure no parts came loose during shipping In the Commonwealth of Massachusetts This product must be installed by a licensed plumber or gas fitter When using ball type gas shut off valves they must be the T handle type When using a fl...

Страница 3: ...able wrench 1 4 Nut driver Drill Pliers Safety glasses Tape measure Gloves Materials You May Need Gas line shut off valve Pipe joint sealant that resists action of natural and LP gases Flexible metal appliance connector 3 4 or 1 2 NPT x 1 2 I D Never use an old connector when installing a new range Flare union adapter for connection to gas supply line 3 4 or 1 2 NPT x 1 2 I D Flare union adapter f...

Страница 4: ...subject to strong drafts Any openings in the floor or wall behind the range should be sealed Make sure the openings around the base of the range that supply fresh air for combustion and ventilation are not blocked by carpeting or woodwork This range is for indoor household use only Do not install the range in areas exposed to the weather and or water If the range is located near a window do not ha...

Страница 5: ...nstruction and Safety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A or with local codes When this range is installed in a mobile home it must be secured to the floor during transit Any method of securing the range is adequate as long as it conforms to the standards listed above A four wire power supply cord or c...

Страница 6: ...han 15 32 12 mm from any adjacent surface 30 76 2 cm 36 91 4 cm 15 38 1 cm 30 76 2 cm Minimum 13 33 0 cm Maximum depth for cabinets above countertops Front edge of the range side panel forward from cabinet 0 To cabinets below cooktop and at the range back 1 4 0 64 cm 5 12 7 cm Minimum Minimum Dimensions 30 76 2 cm minimum clearance between the top of the cooking surface and the bottom of an unprot...

Страница 7: ... the leveling legs with a wrench Extending the legs slightly may also make it easier to insert the rear leg into the anti tip bracket Use a level to check your adjustments Place the level diagonally on the oven rack and check each direction for level First check direction Then check direction If the level doesn t show level on the rack adjust the leveling legs with a wrench 1 2 Optional Rear Fille...

Страница 8: ... connector should be used unless local codes require a hard piped connection A manual valve shall be installed in an accessible location in the gas piping external to the appliance for the purpose of turning on or shutting off gas to the appliance Never reuse an old connector when installing a new range To protect against gas leaks use a qualified pipe joint sealant on all external threads 1 Insta...

Страница 9: ... conduit connections or 4 wire conduit connections Warning Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary The power supply cord and plug should not be modified If it will not fit the outlet have a proper outlet Installed by a qualified electrician Using an extension cord to connect the power is prohibited Connect the power cord...

Страница 10: ...middle neutral or ground wire which is white of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block Failure to do so can result in electrical shock severe personal injury or death Install the power cord as follows...

Страница 11: ...inal block The center screw now attaches the bent up ground strap to the block 4 wire connection Ground strap Terminal block Conduit connection plate Ground screw Black White Red Bend strap up and attach If screws are not tightened securely it can result in electrical spark and severe personal injury or death 3 Wire Connection Conduit Install the conduit as follows Remove the conduit connection pl...

Страница 12: ...IN LB 4 wire connection Terminal block Black White Red Ground strap Wire ends Conduit connection plate Bend strap up and attach Ground wire Ground screw If screws are not tightened securely it can result in electrical spark and severe personal injury or death Engaging the Anti tip Device Move the range close enough to the opening to plug into the receptacle Slide the range into position ensuring t...

Страница 13: ...r the burner ignites rotate the knob out of the Lite position Try each burner in succession until all burners have been checked Quality of Flames The combustion quality of the burner flames needs to be confirmed visually A Yellow flames Call for service B Yellow tips on outer cones This is normal for LP gas C Soft blue flames This is normal for natural gas NOTE With LP gas some yellow tipping on o...

Отзывы: